Seametrics FT420 v.2 User Manual

Ar ch ive d

Advertising
background image

FT420 Flow Computer
Instructions

The FT420 is a loop-powered microcontroller-based
transmitter/indicator. It displays rate and total, and pro-
vides a 4-20 mA analog signal proportional to flow. A
programmable pulse output, high flow or low flow alarm
are also standard for metering pump control or data
logging.

The rugged cast-aluminum housing is gasketed for maxi-
mum environmental protection, and the electronics are
potted into a solid block of urethane. A membrane key-
pad allows settings to be changed without removing the
cover. The wall mount version comes with brackets for
mounting. An adapter kit (part No. MK20) allows field
mounting on 80-series flow sensors. The FT420 can
also be factory installed on a TX100/200 series sensor
or WT meter.

SET

Features

Sturdy gasketed cover

with electronics

potted in

Removeable foot brackets

for wall mounting

Large rate numerals

Easy set-up

prompts

Triple bosses for

watertight input/output

connections

10.5

2341678.9

SET K

RESET

Two wire

4-20 mA output standard

Specifications

General Information

Power

4 mA DC (4-20 mA loop),
12-32 VDC

Display

Rate

6-digit autorange, 1/2"
character height

Total

8-digit, 5/16" character
height

Pulse Output

• 0.1 second open collector
pulse (scaled)
• high alarm or low alarm
• sensor pulse (unscaled)

Input

Pulse frequency + 5 VDC

K factor Range

0.050 - 999999.9

Pulse Output Range

0.1 - 200,000 units/pulse

Flow Alarm Output Range

0.1 - 999999.99

Temperature

0 C - 70 C

Environmental

NEMA 4X

LT-10605A