Setting

The DIP switches under the front clear cover are used
for accumulator and timer settings. As the front plate
states, the setting is the sum of the numbered switches
turned on. Any number from one to 127 can be set.
The multiply-by-ten switch must be used for numbers
from 130 to 1,270.

The easiest way to set a number is to begin with the
largest number which is less than the target, then add
smaller numbers until the target is reached. See illus-
tration at right.

Example 1: The desired accumulator count is 12. First
turn on the 8 switch, followed by the 4.
(8 + 4 = 12)

Example 2: The desired time is three minutes (180
seconds). Use 16 and 2 to set 18, then use the multi-
ply-by-ten switch to get 180.

COUNTS

32

16

8

4

2

1

64

32

16

8

4

2

1

SECONDS

64

OFF

ON

T

I

M

E

R

A

C
C
U

M

12 counts

180 seconds

This switch "ON"
multiplies by 10

This switch "ON"
multiplies by 10

Example 1

Example 2

3 of 4

GND

SIGNAL

EXTERNALLY-PACED
METERING PUMP

DRY CONTACT
TYPE METER (MR,WPR)

GND

GND

SIGNAL

SIGNAL

+12 VDC

+12 VDC

PUMP+

SOLID STATE TYPE
METER (ME,IP,WT)

SOLID STATE TYPE
METER (ME,IP,WT)

PT32 CONNECTIONS DIAGRAM

Ground

Signal

Pump

+

5 AMP AGC FUSE

110 VAC

INPUT

110 VAC
OUTPUT

Hot Normally Closed

Hot Normally Open

Neutral

Ground

+ 12 VDC

Neutral

Ground

Hot

PT33 CONNECTIONS DIAGRAM

Hot

Neutral

Ground

High Flow Relay

NC NO N G

NC NO N G

Hot Normally Closed

Hot Normally Open

Neutral

Ground

Ground
Neutral

Hot Normally Open

Hot Normally Closed

110 VAC Input

Low Flow Relay

JP1

For Sequential timer operation,
remove jumper and replace to
connect these two pins.

JP2

JP2

JP1

DIS

CON

TIN

UED