Flash tube replacement, Specifications – SHIMPO DT-725 User Manual

Page 3

Advertising
background image

When FPM reading is displayed but unit is not flashing,

flash tube may need to be replaced.

1. Unplug line cord from power line. Turn power switch

OFF. Wait a few minutes until stroboscope is cool
before replacing flash tube.

2. Remove protective window by removing the 4 screws.

3. Use a rag and pull the tube out of its socket by rocking

it slightly up and down. Do not use bare hands to
remove tube, it may break and cause injury.

4. Insert new tube using the technique mentioned above.

Make sure that the tube is placed properly in the socket
otherwise it will touch the reflector. Tube should be set
symetrically within the neck of the reflector.

5. Replace protective window.

Flash Tube Replacement

MODEL

MODEL

MODEL

MODEL

MODEL

DT

DT

DT

DT

DT- 725(DC)

- 725(DC)

- 725(DC)

- 725(DC)

- 725(DC)

FLASHING RANGE

FLASHING RANGE

FLASHING RANGE

FLASHING RANGE

FLASHING RANGE

40 — 12,500 FPM (Flashes Per Minute)

ACCURACY

ACCURACY

ACCURACY

ACCURACY

ACCURACY

±0.02% of reading

RESOL

RESOL

RESOL

RESOL

RESOLUTION

UTION

UTION

UTION

UTION

0.1 ,

40.0 – 4,999.9 FPM

0.2 , 5,000.0 – 7,999.8 FPM
0.5 , 8,000.0 – 9,999.5 FPM
1

.0

, 10,000

.0

– 12,500

.0

FPM

DISPL

DISPL

DISPL

DISPL

DISPLAAAAAYYYYY

5-Digit LED, 0.3" (8 mm) height

R

RR

RRAAAAATE

TE

TE

TE

TE

Divide by 2, Multiply by 2

UPDA

UPDA

UPDA

UPDA

UPDATE TIME

TE TIME

TE TIME

TE TIME

TE TIME

Ext. mode: varies with flashing rate

OPER

OPER

OPER

OPER

OPERAAAAATING TIME

TING TIME

TING TIME

TING TIME

TING TIME

1 hour when fully charged

FLASH TUBE POWER/LIFE

FLASH TUBE POWER/LIFE

FLASH TUBE POWER/LIFE

FLASH TUBE POWER/LIFE

FLASH TUBE POWER/LIFE

Xenon, 10 W, 100 million flashes

FL

FL

FL

FL

FLASH DUR

ASH DUR

ASH DUR

ASH DUR

ASH DUR AAAAATION

TION

TION

TION

TION

10 - 15

µ

s

SIGNAL OUTPUT

SIGNAL OUTPUT

SIGNAL OUTPUT

SIGNAL OUTPUT

SIGNAL OUTPUT

NPN Open Collector (24 VDC max.,
50 mA) 150

µ

s typical

PHASE SHIF

PHASE SHIF

PHASE SHIF

PHASE SHIF

PHASE SHIFTTTTT

Internal mode only by using the “+”
and “–” switches

EXT

EXT

EXT

EXT

EXT. TRIGGER

. TRIGGER

. TRIGGER

. TRIGGER

. TRIGGER

a) 12-24 VDC thru a 3-wire NPN output

sensor (requires external power supply)

INPUT SIGNAL

INPUT SIGNAL

INPUT SIGNAL

INPUT SIGNAL

INPUT SIGNAL

b) 12 VDC thru a 2-wire proximity

sensor (leakage current 1 mA max.,

Load current 8 mA min.)
c) Switch or Relay contact

LLLLLOW BA

OW BA

OW BA

OW BA

OW BATTTTTTERY INDICA

TERY INDICA

TERY INDICA

TERY INDICA

TERY INDICATOR

TOR

TOR

TOR

TOR

Yes

OPER

OPER

OPER

OPER

OPERAAAAATING TEMPER

TING TEMPER

TING TEMPER

TING TEMPER

TING TEMPERAAAAATURE

TURE

TURE

TURE

TURE

32° – 104° F (0 – 40° C)

DIMENSIONS

DIMENSIONS

DIMENSIONS

DIMENSIONS

DIMENSIONS

9" L x 4.3" W x 8.5" H
(Height includes handle)

WEIGHT

WEIGHT

WEIGHT

WEIGHT

WEIGHT

2.75 lbs (1.25 Kgs)

ACCESSORIES AVAILABLE

ACCESSORIES AVAILABLE

ACCESSORIES AVAILABLE

ACCESSORIES AVAILABLE

ACCESSORIES AVAILABLE

Carrying Case

Specifications

Advertising