4 Relay Output and Power Supply

3.4. Applying Power

After all wiring is completed, apply power to the KT-300. Connect the battery

leads to the battery, then connect the AC transformer. Then, connect power to the

KT-PC4204: the battery leads followed by the AC transformer.

Note: Do not connect the power until all wiring is complete.

4.

Assigning the KT-PC4204 module
Once all wiring is complete, the module must be assigned to the system. To

assign the module, perform the following steps:
1.

Establish communication between the PC and the controller,

2.

Remove the tamper switch wire (or only the wire if tamper switch is not

used),

3.

A serial number should be displayed on the screen, in the same window

where is the serial number appears, you should see the type of module and

on which controller it is connected,

4.

From the software, select the functionality of the module and enter the serial

number in the appropriate field (see your software reference manual under

controller definition -- Assigning modules for more details),

5.

If the module is used in “repower” mode, assign an “all valid” schedule to

relay 1 and assign the module’s functionality to “relay 1 to 4” in your

software.

Note: Don’t forget to reconnect the tamper switch (or the wire, if there is

no tamper switch).
Note: If the module is uses as a “repower” module, ensure that Jumper

J1 is set to “Combus Relay” position.

Terminal Connections

Module no.: ______________________________________________________________________________________
Date of installation: _______________________________________________________________________________
KT-300 Name: ____________________________________________________________________________________
KT-300 SITE NAME: _______________________________________________________________________________
KT-300 Serial Number: _____________________________________________________________________________
AUX: ___________________________________________________________________________________________
COMBUS (FROM):_________________________________________________________________________________
COMBUS (TO): ___________________________________________________________________________________

Repower: YES:



(if yes, assign an “All valid” schedule to Relay 1) NO:



RLY1: Normally open (NO): ________________________________________________________________________

Normally closed (NC): _______________________________________________________________________

RLY2: Normally open (NO): ________________________________________________________________________

Normally closed (NC): _______________________________________________________________________

RLY3: Normally open (NO): ________________________________________________________________________

Normally closed (NC): _______________________________________________________________________

RLY4: Normally open (NO): ________________________________________________________________________

Normally closed (NC): _______________________________________________________________________

FCC & IC COMPLIANCE STATEMENT

CAUTION: Changes or modifications not expressly approved by Kantech Systems Inc. could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause

interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart

“B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential installation. However, there is no guarantee

that interference will not occur in a particular installation. If this equipment does cause interference to television or radio reception, which can be determined by turning the

equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

Re-orient the receiving antenna

Relocate the alarm control with respect to the receiver

Move the alarm control away from the receiver

Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared

by the FCC helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office,

Washington, D.C. 20402, Stock # 004-000-00345-4. This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this

device may not cause harmful interference, and (2) this device must accept any interference received including interference that may cause undesired operation. This class

B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. The KT-300 is also compliant with EN55022: 1994, amendment 1:

1995, Class B.

Advertising