Scope – Spectrex Series 200 Open-Path Gas Detection System User Manual

Page 9

Advertising
background image

Spectrex Inc. - SafEye

TM

200 Gas Detector Manual – TM 792100, Rev. D, May 2004

1

1. Scope

1.1 Product Overview
The SafEye 200 Series IR Open-Path Gas Detector employs an advanced
Flash Source and integrated electronics package to provide high quality and
performance, fast response, line of sight gas monitoring.

SafEye detects ambient combustible gases at LEL.m concentrations over a path
length of up to 459-ft. (140 m), even in harsh environments where dust, fog, rain,
snow or vibration can cause a high reduction of signal. Due to its unique
combination of triple optics and dual-spectrum reference sensor, the SafEye can
maintain operation in up to 90% signal obscuration and ±1 degree of
misalignment.
SafEye has a fast response detection time of no more than 5 seconds. This
feature enables an adequate time to take appropriate safety measures.
The SafEye Source and Detector unit enclosures are ATEX certified EExd
flameproof or EExde with additional separate EExe terminal box connected to the
unit.

This manual consists of a full description of the Detector and its features. It
contains instructions on the installation, operation and maintenance. The system
is intended to be used by qualified personnel.

1.2 Document Overview

This manual describes the Detector and its features and provides instructions on
the installation, operation and maintenance.

This manual is divided into separate sections

as follows:


Section 1.

Scope - a general introduction and overview of the product and the
Manual, with a brief description of its content.

Section 2.

Technical Description - the Detector’s theory of operation.

Section 3.

Operation Mode - the Detector’s operation modes, user interface and
indications.

Section 4.

Technical Specifications - the Detector’s electrical, mechanical and
environmental specifications.

Section 5.

Installation Instructions, including wiring and mode setting.

Section 6.

Operating Instructions and power-up procedures.

Section 7.

Maintenance Instructions and support procedures.

Section 8.

Troubleshooting

Appendix A.

Wiring Selection Tables for electrical wire selection according
to installation configuration.

Appendix B.

Wiring option Configurations - wiring diagrams for
installation.

Appendix C.

Detector and Source Outline Drawing

Advertising