Capacity Data - Cooling Only Unit

Cooling
Duty

Mean

Evaporating

Temperature °C

Ambient

25°C

30°C

35°C

40°C

45°C

Output kW Input kW

Output kW Input kW

Output kW Input kW

Output kW Input kW

Output kW

Input kW

CU1

-5

2.62

0.90

2.45

1.04

2.30

1.19

2.13

1.33

1.96

1.47

0

3.11

0.95

2.92

1.08

2.73

1.23

2.55

1.37

2.35

1.51

5

3.70

0.98

3.50

1.12

3.30

1.26

3.10

1.41

2.90

1.55

10

4.32

1.02

4.11

1.15

3.90

1.28

3.67

1.44

3.44

1.59

CU1.5

-5

3.57

1.27

3.35

1.47

3.14

1.68

2.91

1.87

2.68

2.08

0

4.25

1.31

4.02

1.52

3.79

1.71

3.55

1.92

3.31

2.13

5

5.05

1.38

4.79

1.58

4.51

1.78

4.24

1.99

3.97

2.19

10

5.90

1.44

5.62

1.63

5.33

1.81

5.02

2.04

4.70

2.25

CUS2

-5

4.01

1.09

3.76

1.26

3.52

1.44

3.27

1.61

3.01

1.79

0

4.77

1.13

4.51

1.31

4.25

1.47

3.98

1.65

3.71

1.83

5

5.67

1.19

5.37

1.36

5.06

1.53

4.76

1.71

4.45

1.88

10

6.62

1.24

6.30

1.40

5.98

1.56

5.63

1.75

5.27

1.93

CUS2.5S

-5

5.97

1.74

5.61

2.01

5.24

2.26

4.83

2.55

4.41

2.83

0

7.12

1.82

6.73

2.08

6.34

2.34

5.90

2.63

5.46

2.91

5

8.40

1.93

7.98

2.18

7.55

2.42

7.06

2.72

6.56

3.01

10

9.80

2.03

9.32

2.27

8.84

2.51

8.26

2.80

7.68

3.08

CUS2.5T

-5

5.90

1.72

5.69

2.00

5.47

2.27

5.27

2.54

5.53

2.82

0

7.18

1.83

6.81

2.08

6.43

2.34

6.07

2.59

5.66

2.90

5

8.40

1.91

7.99

2.17

7.57

2.42

7.13

2.71

6.68

2.99

10

9.70

2.02

9.25

2.27

8.79

2.51

8.31

2.79

7.82

3.07

CUS3

-5

6.99

2.13

6.62

2.44

6.26

2.75

5.91

3.07

5.50

3.44

0

8.28

2.27

7.86

2.54

7.44

2.81

6.99

3.14

6.54

3.53

5

9.69

2.38

9.20

2.69

8.72

2.96

8.22

3.30

7.67

3.63

10

11.20

2.51

10.67

2.79

10.12

3.09

9.55

3.42

8.99

3.74

CUS3.5

-5

8.66

2.48

8.19

2.79

7.71

3.10

7.23

3.42

6.75

3.73

0

10.38

2.60

9.82

2.91

9.25

3.21

8.72

3.54

8.18

3.86

5

12.35

2.77

11.56

3.05

10.76

3.33

10.24

3.66

9.72

3.98

10

14.18

2.93

13.29

3.20

12.39

3.46

11.89

3.79

11.39

4.12

CUS4

-5

10.56

2.50

9.85

2.98

9.18

3.46

8.54

3.95

8.54

3.95

0

12.44

2.63

11.74

3.11

11.05

3.59

10.32

4.07

9.78

4.61

5

14.54

2.86

13.80

3.33

13.05

3.79

12.37

4.27

11.75

4.80

10

16.95

3.11

16.17

3.56

15.38

4.00

14.51

4.45

13.62

5.00

1

Output kW refers to the compressor duty.

2

Input kW refers to the compressor input power only.

3

Cooling data for a cooling only unit.

Advertising