Aleco AirFlex Insect Barriers User Manual

Air-flex® insect barrier installation instructions

Advertising
background image

FOR ANY QUESTIONS OR COMMENTS, PLEASE CONTACT AN ALECO REPRESENTATIVE

2720 E. Avalon Ave. Muscle Shoals, AL 35661 ● Phone (256) 248-2402 or toll free 1-800-633-3120

Fax: 1-800-750-9616 ● email:

[email protected]

Diagram 1

Under Header (Lintel) Position

Wall

HTP Hardware

Bracket

Bullet

Strips

Diagram 2

Wall (Header) Position

Wall

HTP Hardware

Bracket

Bullet

Strips

Diagram 3

Front View Strip Spacing

Air-Flex® Insect Barrier

Installation Instructions

Using the MaxBullet® HTP System

TOOLS NEEDED

•

Pen or Pencil to Mark Drill Holes

•

Drill

•

Step Stool or Ladder

•

Utility Knife to Cut Strips

IMPORTANT

Some door models feature alternating clear PVC strips.

Prior to installation,

unroll all door strips and place them on

a clean, flat surface in a warm atmosphere for a minimum of

twenty-four (24) hours. This will allow the strips to return to

their original form.

1. Mount the MaxBullet® hardware bracket in either

the under header or wall position shown in

Diagrams 1 and 2 using the appropriate fasteners

supplied.

2. Press the door strips onto the “bullets” of the

hardware bracket making certain that the

concave sides are facing each other. Attach strip

numbers 1 and 3 (see Diagram 3) leaving desired

spacing between strips as indicated below

(Diagram 4).

3. Attach strip number 2 over strip numbers 1 and 3

(Diagram 3).

4. Attach all of the remaining door strips in the same

manner as in Steps 2 and 3.

Diagram 4

PARTIAL OVERLAP 50%

FULL OVERLAP 100%

● web:

www.aleco.com

P/N 477254

(Rev 0511)

Advertising