Therefore, when programming an AMR module, the Actual Index Pressure Factor – as supplied by the meter manufacturer– should

be used rather than the calculated Pressure Factor. This will avoid correlation issues between the AMR module and the reading on

the index.
The installer must be extremely careful to determine and program the correct Pressure Factor since errors can be

significant The utility meter department should be consulted to understand the utility applications of high pressure before

installation begins
Below are examples of fixed pressure factor indexes, and the resultant Pressure Factor, calculated from information detailed

on the index itself in addition to the Actual Index Pressure Factor provided by the meter manufacturer

Pressure Factor programmed to be 1 3091

Calculated PF:

14 4 psi + 5 0 psi

14 73 psi

= 1.3170

Actual PF (provided by meter manufacturer):

= 1.3091

Pressure Factor programmed to be 1 1111

Calculated PF:

14 4 psi + 2 0 psi

14 73 psi

= 1.1134

Actual PF (provided by meter manufacturer):

= 1.1111

Step 7: Determine Direction of Meter Drive Rotation (ORION SE/ME only)

The ORION SE endpoint has the ability to monitor the direction of rotation of the meter drive, and provide an alert if

the direction changes to the opposite direction A change in direction, or reverse flow, might be an indicator of theft or

tampering
The direction of rotation of the meter drive shaft needs to be determined and programmed

NOTE:

N

The meter drive shaft may not rotate in the same direction as the index Drive Dial due to coupling through the

gearing

Several common meters are shown below, along with the direction of rotation of the meter drive shaft However, given the

variety of meter styles and designs, you should verify the direction of rotation of the meter drive on all meters that will utilize

an ORION SE endpoint Verification is done by removing the index and observing the meter shaft rotation while the meter is

in operation