6.5
-
OPERATING MODE 3 - Output adjusted 
by 0-10VDC input signal 
In this mode, the pump’s motor speed is adjusted 
automatically based on the value of the 0-10VDC 
input signal. Any motor speed can be assigned to 
either the minimum or maximum DC input signal 
values. However, the programmed minimum VDC 
value must be less than the programmed maximum 
VDC value. The ALARM and SERVICE icons will 
blink if the programming is in error. To assign the 
minimum and maximum motor speed and the 
minimum and maximum VDC input signal values:
4 Set the pump for mode 3. Press the MODE button
until MODE 3 is shown on the LCD display. The % 
SPEED or VDC icon will light depending on the 
current display setting. The large 3-DIGIT LCD will 
indicate the current motor speed or the VDC input 
value. 
4 Enter the programming mode. At the same time,
press the RUN/STANDBY and MODE buttons. A 
blinking ARROW will point to the word PROGRAM 
indicating the program mode is activated. A blinking 
ARROW will point to the word MINIMUM indicating 
the minimum value is ready to be programmed. The % 
SPEED icon will blink indicating the percentage of 
speed is ready to be programmed.
4 Enter the motor speed at the minimum VDC input
signal value. Press the FIELD button to select the 
digit to program. The digit will blink when selected.
4 Press the DIGIT button to change the selected digit.
4 Repeat until all digits are programmed.
4 Press the mode button. The % SPEED icon will stop
blinking and the VDC icon will blink indicating the 
minimum VDC value is ready to be programmed. The 
currently programmed minimum value is shown on 
the 3-DIGIT LCD.
4 Enter the minimum VDC input signal value. Note:
this value must be less than the maximum VDC input 
signal value. Press the FIELD button to select the digit 
to program. The digit will blink when selected.
4 Press the DIGIT button to change the selected digit.
4 Repeat until all digits are programmed.
4 Press the mode button. The VDC icon will stop
blinking and the % SPEED icon will blink. The 
ARROW next to the word MAXIMUM will blink 
PROGRAM MODE 3
% speed at the minimum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
% SPEED
MODE
RUN MODE 3
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
MODE
VDC
PROGRAM MODE 3
minimum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
MODE
VDC