Caution, Warning, Fig. 4.4 wiring diagram - standard models – Blue-White C-1500N CHEM-FEED Diaphragm Pump User Manual

Page 5: Motor leadwires

Advertising
background image

1

2

3

5

4

6

7

8

9

10

C-1500N

Page 5

4.2

Electrical Connections

4.2.1

Input Power Connections

Note: When in doubt regarding your electrical installation, contact a licensed

electrician.

The C-1500N is supplied with either a ground wire conductor and a grounding
type attachment plug (power cord) or a junction box for field wiring.

POWER CORD MODELS -To reduce the risk of electric shock, be certain
that the power cord is connected only to a properly grounded, grounding type
receptacle.

JUNCTION BOX MODELS -To reduce the risk of electric shock, be certain
that a grounding conductor is connected to the green grounding conductor
located in the junction box.

FIG. 4.4 WIRING DIAGRAM - STANDARD MODELS

AC
MOTOR

INPUT

VOLTAGE

115V 60Hz

HOT

LEADWIRE

NEUTRAL

LEADWIRE

GROUND

LEADWIRE

230V 60Hz

BLUE or YELLOW

BLUE

BROWN

RED

GREEN

GREEN

GREEN

MOTOR LEADWIRES

Neutral

Hot

Ground (green)

Earth Ground (green)

Common

Hot

AC

Input

Power

220V 50Hz

BLACK or YELLOW

BLACK or YELLOW

* Yellow leadwire : thermally protected motor
Black or Blue leadwire: standard impedance protected motor

*

*

*

24V 60Hz

WHITE

GREEN

BLUE

*

To prevent chemical overdosing,

disconnecting power to the circulation system

must also disconnect power to the pump.

!

CAUTION

SHOCK

!

WARNING

Risk of electric shock.

Be certain to connect the

pump to the proper supply voltage. Using the

incorrect voltage will damage the pump and

may result in injury. The voltage requirement is

printed on the pump serial label.