F-2000, 0 features 2.0 applications, 0 specifications – Blue-White F-2000 – Sensor User Manual

Page 3: 1 physical

Advertising
background image

F-2000

Page 3

1.0 FEATURES

2.0 APPLICATIONS

Model RT

! Measure and display the rate of flow
! Measure and display the total flow

Model AO

! Measure and display the rate of flow
! Measure and display the total flow
! Control external devices with 4-20mA

control signal

! Control external devices with 0-10VDC

control signal

Model PC

! Measure and display the rate of flow
! Measure and display the total flow
! Maintain a flow rate range alarm
! Trigger a high flow rate alarm
! Trigger a low flow rate alarm
! Manually controlled batch processing
! Timed auto-reset batch processing
! Proportional flow chemical pump process

control

! Battery powered rate and total

! Extended battery life mode

(screen blanks after 30 seconds)

! Easy to read, eight digit LCD display

! Installs quickly on existing pipe

! Factory programmed

! Field programmable front panel push buttons

! No pressure drop

! Weather resistant enclosure (NEMA 4X)

! Corrosion resistant PVDF sensor

! Corrosion resistant ABS enclosure

! High accuracy

! Extended flow range

! Front panel security lockout

! Minimal maintenance required

3.0 SPECIFICATIONS

3.1

Physical

Maximum Working Pressure ...... ............300 psig (20.7 bar)

o

o

Maximum fluid temperature........ ............200 F (93 C) - saddle and sensor only

o

o

200 F (93 C) - polypropylene and PVDF inline units

o

o

140 F (60 C) - molded PVC tee units

o

o

140 F (60 C) - when mounted on PVC pipe

o

o

o

o

Ambient temperature range........ ............32 F (0 C) to 110 F (43 C)

Enclosure ......... ............ ............ ............NEMA 4X (acceptable for outdoor use)

NOTE: Protect the LCD display from direct sunlight.

Sensor Accuracy ........... ............ ............±1% of full scale reading

Repeatability..... ............ ............ ............±1% of full scale reading

Power requirements ...... ............ ............15 VDC Nominal (12 - 24 VDC Absolute - DO NOT EXCEED 24.0 VDC)

Model RT units only....... ............Four standard AA alkaline batteries or 12-24VDC Plug in transformer

(Battery life expectancy 1 year minimum)

All units ............ ............ ............12-24VDC (plug-in transformer supplied)

Model AO analog output board... ............Linear, Non-isolated, powered loop. 250 ohm max for 4-20 ma / 500

ohms minimum for 0-10 VDC

Model PC Process control board ............Relay SPDT, NO/NC

Maximum switching load

8 amps @ 115 VAC, 220 VAC, 230 VAC
7 amps @ 30 VDC (resistive load)

Maximum fluid debris size .......... ............0.020” diameter

F-2000

Page 2

TABLE OF CONTENTS

Section

Heading

Page

1.0

Features

3

2.0

Applications

3

3.0

Specifications

3

3.1

Physical

3

3.2

Dimensional Drawing

4

3.3

Temperature vs. Pressure Graph

4

4.0

Flow ranges

5

5.0

Mounting Options

6

6.0

Electrical Wiring Connections

8

6.1

Enclosure Knock-Out Instructions

8

6.2

Optional Circuit Board Installation

8

6.3

Model RT Circuit Board Wiring

9

6.4

Model FHXX and FCXX Sensor Wiring

10

7.0

Operation

11

7.1

Theory of operation

11

7.2

Model RT Operation

11

7.2.1

Model RT Applications

11

7.2.2

Model RT Features

12

7.2.3

How to Determine Calibration Constants

12

7.2.4

Programming the Model RT

15

7.2.5

Calibration Constants

16

7.3

Programming flow chart

18

8.0

Maintenance

19

8.1

Troubleshooting

19

F-2000 parts list

20

. . .

F-2000 exploded view

21