Panel Mounting
Panel mounting is accomplished following most of the steps
listed for wall mounting. Some of the differences are listed
below:

• Use the appropriate length and type of mounting screws for se-
curing the mounting plate (A1) to the panel.

• If the high and low references are remote from the panel, con-
nect the pressure sensing tubing to the appropriate ports on the
gage.

• If clearance behind the gage is a concern, the side ports on the
gage may be used.

To use the side ports, install the factory supplied plugs on the

back ports and install the barbed fittings supplied with the gage
on the side ports.
Note: Install the barbed fittings on the side ports after the gage
is mounted on the panel.

A3

LOW

HIGH

LOW

HIGH

A1

A2

INSTALLATION DIAGRAM