Specifications, The bottom air intake, The upper air intake – Antec New Solution Series User Manual

Page 6: The rear air intake, Cpu air guide, The power supply air intake

Advertising
background image

5

Note regarding using fan speed controllers with TriCool fans:

The minimum voltage to start the fan is 5V. We recommend our users set the fan
speed to High if the fan will be connected to a fan control device or to the
Fan-Only connector found on some Antec power supplies. A fan-control device
regulates the fan speed by varying the voltage to it. The voltage may start as low
as 4.5 V to 5V. Connecting a TriCool™ set on Medium or Low to a fan-control
device may result in the fan not being able to start. The already lowered voltage
from the fan control device will be further reduced by the TriCool circuitry below 5V.

Specifications

Size:

120 x 120 x 25.4 mm

Rated Voltage:

DC 12V

Operating Voltage:

10.2V ~ 13.8V

The Bottom Air Intake

There are intake vents at the bottom of the case right under the HDD chamber.
Fresh cool air will flow through the vents through the hard drives, and then flow
into the motherboard chamber and exhaust by the two 120mm TriCool fans.
Note: Do not place the NSK2480 on a soft surface or over anything that will block
the bottom air vents.

The Upper Air Intake

There are vents on the top panel above the PCI expansion slots. Fresh air will flow
through them into the motherboard chamber to cool the VGA card.
Note: Do not place anything on top of the NSK2480 that will block the top air vents

The Rear Air Intake

There are vents right above the rear I/O panel and on the PCI expansion slot
covers to bring in fresh air to help cool the CPU and VGA card.

CPU Air Guide

The CPU Air Guide and rear air intake work together to provide fresh air to the
CPU cooler to enhance the CPU cooling. The CPU Air Guide consists of several
sections that can be adjusted to best suit each individual motherboard
CPU position.

The Power Supply Air Intake

There are vents on the left side of the case to bring fresh air into the power supply
chamber to cool the power supply.
Note: Please leave at least 1” (2.5cm) between the left side of the case and

Speed

Input

Current

Air Flow

Static Pressure

Acoustical

Noise

Input

Power

High

2000 RPM

0.24A
(Max.)

2.24 m³ / min

(79 CFM)

2.54 mm-H

2

O

(0.10 inch-H

2

O)

30 dBA

2.9 W

Medium

1600 RPM

0.2A

1.59 m³ / min

(56 CFM)

1.53 mm-H

2

O

(0.06 inch-H

2

O)

28 dBA

2.4 W

Low

1200 RPM

0.13A

1.1 m³ / min

(39 CFM)

0.92 mm-H

2

O

(0.04 inch-H

2

O)

25 dBA

1.6 W

Advertising