Range No.
3
4
5
6
7
8
9
psig (bar)
5-40 (0.34 - 2.76)
10-70 (0.69 - 4.82)
25 - 200 (1.72 - 13.78)
50 - 350 (3.45 - 24.12)
75 - 550 (5.17 - 37.90)
100 - 900 (6.89 - 62.01)
200 - 1400 (13.78 - 96.46)
Approx. Deadband (fixed)* psig (bar)
2 (0.14)
4 (0.28)
8 (0.55)
15 (1.03)
30 (2.07)
50 (3.45)
75 (5.17)
Max. press. without bursting psig (bar)
3000 (206.7)
3000 (206.7)
3000 (206.7)
3000 (206.7)
3000 (206.7)
3000 (206.7)
3000 (206.7)
Operating Rages/Deadband
Code
D
J
No. Switches Action
1 Snap SPDT
1 Snap SPDT
125V
15A
15A
Electrical Rating
AC Capacity
250V
15A
15A
480V
NA
15A
DC Capacity
125V
0.5A
(2)
250V
0.25A
(2)
125V
1/8
1/8
250V
1/4
1/4
125V
NA
NA
250V
NA
NA
DC
AC
Horse Power
* Deadband is 10% larger when using 316SS diaphragm or Code F switch.
Note (2) Resistive