Dwyer DKT-1 User Manual

Model dkt-1 pocket-size thermocouple thermometer, Dwyer instruments, inc

Advertising
background image

LCD ERROR MESSAGES

The thermometer incorporates visual diagnostic messages

as follows:

‘Er2’: Displays when the thermometer is exposed to rapid

changes in the ambient temperature.

‘Er3’: Displays when the ambient temperature exceeds

32°F (0°C) or 122°F (50°C). The thermometer should be

allowed plenty of time (minimum 30 minutes) to stabilize to

the working/room temperature.

For all other error messages it is necessary to reset the ther-

mometer. To reset it, wait for the instrument to power off,

remove the battery and wait for a minimum of one minute,

reinsert the battery and turn it on. If the error message

remains please contact Dwyer Customer Service

Department for further assistance.

Model DKT-1 Pocket-Size Thermocouple Thermometer

Specifications - Installation and Operating Instructions

Bulletin T-15

DWYER INSTRUMENTS, INC.

Phone: 219/879-8000

www.dwyer-inst.com

P.O. BOX 373 • MICHIGAN CITY, INDIANA 46361, U.S.A.

Fax: 219/872-9057

e-mail: [email protected]

The Model DKT-1 Pocket-Size Thermocouple

Thermometer accurately monitors temperatures in a vari-

ety of applications. The wide measurement range and

selectable engineering units allow users to easily view read-

ings in either °F or °C . The automatic power down feature

conserves battery life. This compact thermometer accepts

any K-type thermocouple sensors (sold separately) with

min-plug connectors.

PROBE MEASUREMENTS

With the appropriate K-type thermocouple connected to

the thermocouple plug, the thermometer is ready to take

measurements. Power the thermometer on by pressing the

ON/HOLD button. The device will begin reading. The °F or

°C designator will flash while taking readings. The ther-

mometer will automatically power down after 4 minutes to

conserve battery life. Pressing the “ON/HOLD” key during

measurements will hold the current reading for 15 seconds.

After 15 seconds, the device will power down to conserve

battery life.

ENGINEERING UNITS

The thermometer can measure °F or °C. To change the

units, turn on the unit by pressing the “ON/HOLD”. Press

the “ON/HOLD” key again and the words “hold” will display.

While the display is holding the last reading, press the

“°C/°F” button to change the units.

SPECIFICATIONS

Range:-83.2 to 1999°F (-64 to 1400°C).

Ambient Operating Temperature: 32 to 122°F

(0 to 50°C).

Accuracy: +/- 1% of Reading or 1.8°F (1.0°C).

Probe Connection: K-type mini-jack.

Resolution: 0.1°F/°C.

Battery Life: CR2032 lithium battery - estimated 100

hours continuous use.

Weight: 1.42 oz (40.15g).

Agency Approvals: CE.

1-45/64

(43.26)

51/64

(20.24)

3-5/64

(78.18)

T-15:E-90-RH 6/12/08 9:56 AM Page 1