Camera interfaces

Hardware Installation Guide V2.0.0

55

Outputs OSCAR/MARLIN

The OSCAR and MARLIN cameras have 2 non-inverting outputs with open
emitters. These are shown in the following diagram:

Figure 31: Output schematics with external resistor R (OSCAR/MARLIN)

Parameter

Test condition

Value

Emitter current

Max. 500 mA

Emitter collector voltage

Max. 45 V

Figure 32: Output parameters (OSCAR/MARLIN)

OutVCC

Resistor value

5 V

1 k

Ω

12 V

2.4 k

Ω

Figure 33: OutVCC (OSCAR/MARLIN)

Note

L

OSCAR/MARLIN

•

Voltage above +45 V may damage the optical coupler.

•

The output connection is different to the AVT Dolphin
series to achieve higher output swing.

•

Depending on the voltage applied at OutVCC and the
type of input which you want to drive, it may be neces-
sary to switch an external resistor in series between
GPOut1 and ground. The use of 1 k

Ω @ 5 V or 2.4 kΩ @

12 V can be recommended. Typical delay is not more
than 40 µs.

Note

L

For information on output features (IntEna, Fval, Busy) and
configuration via registers see Technical Manuals.