Dwyer MM10 User Manual

Dwyer Tools

Advertising
background image

OPERATING INSTRUCTIONS

SERIES MM10 DIGITAL MULTIMETER



SAFETY INFORMATION

The following safety information must be observed to insure
maximum personal safety during the operation of this meter.

Do not use the meter if the meter or test leads look damaged, or
if you suspect that the meter is not operating properly.

Never ground yourself when taking electrical measurements. Do
not touch exposed metal pipes, outlets, fixtures, etc., which might
be a ground potential. Keep your body isolated from ground by
using dry clothing, rubber shoes, rubber mats, or any approved
insulating material.

Turn off power to the circuit under test before cutting,
unsoldering, or breaking the circuit. Small amounts of current
can be dangerous.

Use caution when working above DC 60V or AC 30Vrms. Such
voltages pose a shock hazard.

When using the probes, keep your fingers behind the finger
guards on the probes.

Measuring voltage which exceeds the limits of the multimeter
may damage the meter and expose the operator to a shock
hazard. Always recognize the meter voltage limits as stated on
the front of the meter.

GENERAL SPECIFICATIONS

Display:

3-1/2 digit liquid crystal display (LCD) with a maximum

reading of 1999.
Polarity:

Automatic, positive implied, and (-) for negative polarity

indication.
Overload:

(1) or (-1) is displayed on LCD.

Low Battery Indication:

When "

" shows on LCD, battery

needs to be replaced.
Sampling Rate:

2.5 times per second.

Operating Environment:

0°C~40°C 80% RH.

Storage Temperature:

-10°C~60°C 0~80% RH with battery

removed from meter.
Power:

One 006P 9V standard battery.

Battery Life:

150 hours approx.

Dimension:

125 mm (H) x 68 mm (W) x 25 mm (D).

Weight:

150g approx. including battery.

Accessory:

Instruction manual, test leads, (1) 9V battery.


SPECIFICATIONS

DCV

Range Resolution Accuracy

Input

Impedance

Overload

Protection

2V

1mV

0.5% + 1 dgt

20V 10mV

200V 100mV
600V 1V

1.5% + 1 dgt

10MΩ

DC 600V

AC 600V

rms

ACV

Range Resolution

Accuracy

Input

Impedance

Overload

Protection

200V 100mV

2% + 3 dgt

(40 Hz-

500 Hz)

600V

1V

2.5% + 3 dgt

4.5MΩ

DC 600V

AC 600V

rms


DCA

Range Resolution

Accuracy

Input

Impedance

Overload

Protection

2mA 1μA

20mA 10μA

200mA 100μA

1.5% + 1 dgt

0.3V

0.5A Fuse

& Diodes

10A

10mA

2% + 1 dgt

0.7V


Resistance (

)

Range Resolution

Accuracy

Open

Voltage

Overload

Protection

200Ω 0.1Ω

2% + 2 dgt

2KΩ

1Ω

2.8V

20KΩ 10Ω

200KΩ 100Ω

2MΩ 1KΩ

1.5% + 2 dgt

20MΩ 10KΩ

2.5% + 2 dgt

0.3V

DC/AC

500V

rms

Diode Test

Range Resolution

Test

Current

Open

Voltage

Overload

Protection

1mV 1mA ≈2.8V

DC/AC

500V rms

Continuity Test x

Range Resolution Sound

Open

Voltage

Overload

Protection

x

0.1Ω <30Ω

<≈2.8V

AC/DC

500V rms

Transistor hFE

Range

Measuring

Scope

Test

Voltage

Test

Current

Overload

Protection

NPN
PNP

0-1000 <3.2V IB≈10μA

LED

Range

Measuring

Scope

Test

Voltage

Test

Current

Overload

Protection

LED 1.5-3V 3V ≈25mA