RFC1000

Product Overview

The RFC1000 is a high powered transceiver that has a substantially long transmission
range, providing enhanced performance in occluded environments (ovens, refrigerators,
etc.). The RFC1000 also features an external antenna, allowing more flexibility with
mounting positions in both orientation and proximity to metal walls. The device may be
used as a repeater, or directly plugged into the Windows PC.

Transmission Distance

The RFC1000 transmits to other RFC1000s up to 4000 feet maximum typical outdoors/
line of sight, 1000 feet maximum typical indoors/urban. The RFC1000 transmits to data
loggers up to 2000 feet maximum typical outdoors/line of sight, 500 feet maximum typical
indoors/urban. The RFC1000 can connect to a maximum of 64 data loggers. The RFC1000
transmits on a frequency of 2.405 GHz - 2.475 GHz.

Operating Environment

The RFC1000 is rated for use in an environment with temperatures from -20 °C to 85 °C
and a humidity range of 0 %RH to 95 %RH non-condensing. The RFC1000 is rated IP40
and is protected against solids that are greater than 1mm in size. This device is not water
resistant.

LEDs

The red LED indicates that the device has power. The green LED will blink when
communicating with other devices.

Installation Guide

Installing the MadgeTech 4 Software

Insert the Data Logger Software Flash Drive into an open USB port
on a Windows PC. If the autorun does not appear, locate the drive
on the computer and double click on Autorun.exe. Follow the
instructions provided in the Installation Wizard. Software can also
be downloaded from the MadgeTech website at the following
link: www.madgetech.com/software-download.

1. Locate the Autorun.exe file on the Software Flash Drive.

2. Select “Data Logger Software” in the Installer Options window panel.

3. If the Windows PC doesn’t already have .NET 4.0 Framework, installation may

be required.

Note: To see if the .NET 4.0 Framework is installed, go to the Windows Control Panel and

select

Programs. “Microsoft .NET Framework 4.0” would be listed as a Windows program.


Select “Install Data Logger Software” if .NET framework is installed on the Windows
PC, or if installing on a Windows 8 machine.