SMF2-FG Series Media Filter

Operating & Maintenance Manual

PEP Filters

• 322 Rolling Hill Road • Mooresville, NC 28117 • 800-243-4583 •

www.pepfilters.com

704-662-3133 (Outside USA) Page 8 of 16 Fax 704-662-3155

rev. 01/02

pressure switch tubing, and filter tank. The unit should be drained when it is to be shut

down for any period of time. Refer to the Seasonal Shutdown section of the manual for

recommendations.

SEASONAL SHUTDOWN
The following services should be performed when the unit is to be shut down for a

prolonged time period.
1. Shut off all electrical power.
2. Close the shut-off valves in the filter inlet and outlet water lines. For units using a

backwash source other than the system, close the shut-off valve in the line from that

source also.
3. Drain all external piping to and from the filter.
4. Open the manual vent valves and open the drain line to the filter tank and piping. After

the water has drained, close the drain and vent.
5. On manual units only, rotate the valves manually by moving the linkage up and down

to ensure operation without obstruction.
6. Loosen the bolts around the circumference and remove the lid. Lubricate the bolt if

necessary. Replace the O-ring if necessary.

7. Inspect the over-drain assembly and media pack. If the media is contaminated,

remove the foreign material and replace the media if necessary. Replace the filter lid and

secure the bolts.

MAINTENANCE PROCEDURES

PUMP PRE-STRAINER
Warning
: Disconnect all electrical power prior to performing pump maintenance. The

filter pre-strainer basket on the pump inlet must be kept clean and free of debris. Shut off

the power, close the valves, open the air relief valve, remove bolts and lid. Remove the

basket and remove any foreign material. Replace basket, lubricate O-ring, and tighten

clamp.