PEP Filters CARTRIDGE FILTERS User Manual

Page 2

Advertising
background image

SCF Series Cartridge Filter

Operating & Maintenance Manual

PEP Filters

322 Rolling Hill Road

Mooresville, NC 28117

800-243-4583

www.pepfilters.com

704-662-3133 (Outside USA) 2 of 5 Fax 704-662-3155

rev. 11/01

fittings (generally ½” (12.7 mm)) on the filter vessel, install a ball valve and run to

drain. If the filter vessel is not equipped with drain fittings, it is recommended to install

a tee between the filter vessel outlet fitting and outlet ball valve.
Connect a drain line (1/2” ~ 3/4” (12.7 ~ 19.05 mm) recommended) with a small ball

valve to the bottom of the tee and run this line to a suitable drain.

Cartridge Replacement
Cartridge replacement is recommended when the pressure drop across the filter vessel

inlet and outlet exceeds 10 to 12 psig (69 to 83 kPa). Before performing any service on

the SCF filter, disconnect power from the pump motor at the main circuit breaker. Lock

out and tag the circuit breaker.
Isolate the filter vessel from the pump and process by closing the inlet and outlet ball

valves. Fully open the drain valve to vent any remaining pressure and to drain the filter

vessel. Separate the vessel top lid from the vessel body and remove filter cartridge(s).

Make sure that the vessel housing and all o-rings and sealing surfaces are cleaned

before installing new cartridge filters. Install new cartridges and reassemble filter vessel

lid. If so equipped, grease top lid studs and tighten in a ”star” pattern until all are

tightened to 12 ft.-lbs. (16.3 n-m). Close the drain valve and open the filter inlet and

outlet valves. Return the SCF filter to service.

Specifications
Filter Tank
: 304 stainless steel, 150 psig (1,034 kPa)
Process Water Temperature: up to 125

°

F (65.6

°

C)

Distribution system: PVC manifold and stand pipe
Filter Media: Wound polyester cartridge, 0.5 micron to 100 micron (customer

specified)
Maximum operating pressure: 125 psig (862 kPa)

Options
Skid / Frame Assembly
: A channel iron base is available to mount one or more filters,

as well as the Pump: A system matched pump is available to circulate process liquid

through the filter
High Temperature Operation: 300

°

F (149

°

C)

Advertising