h

(Halt Continuous Sampling, Enter Standby)

Description

Exits Continuous Sampling Mode (go) and enters Standby mode (h). If this

command is received while the TCM2.5/2.6 is transmitting an output word, the
remainder of the output word will be sent before the TCM2.5/2.6 changes modes.


Syntax

h<cr>


Output

:[Ennn]<cr><lf>


Related Commands

go (Enter Continuous Sampling Mode)

halt= (Enable Single Character Halt)



halt=

(Enable Single Character Halt)

Description

The halt command during go mode has optionally been made a single character

command using the halt=e command.

Syntax

halt=d<cr>

Output

:[Ennn]<cr><lf>

Valid Values

Input

Description

e

Enable, h command for halting the ouput

d

h <cr> command for halting the output (default setting)

Table 7: Valid

halt= Values

Query Response

halt?

:halt=

Related Commands

go (Enter Continuous Sampling Mode)