COMPONENTS - DIESEL

APEX 86037630

6-5


1. WASTE TANK FULL INDICATOR
LIGHT


This indicator light is activated when the waste
tank is full. When lit the unit will shutdown
protecting the equipment from damage. This
also indicates that the waste tank must be
emptied before the unit can be brought back in
service.
NOTE: Never dispose of waste water in
storm drains, water ways or on ground
areas. Always dispose of waste in
accordance with local, state and federal
laws.


2. GLOW PLUG INDICATOR

After turning the ignition switch counterclockwise
this indicator lamp illuminates during glow plug
warm up. When light goes out, engine is ready
for start.

3. ENGINE HIGH TEMPERATURE SHUTDOWN

INDICATOR

This light when activated signals an over heat
condition with the engine. When this occurs,
troubleshooting is required.

4. VACUUM

GAUGE


This gauge indicates in inches of mercury how
much vacuum the system is producing at any
given time.

5. SOLUTION PRESSURE GAUGE


This gauge registers the amount of pressure in
the system.

6. SOLUTION TEMPERATURE GAUGE


This gauge measures the temperature of the
cleaning solution as it exits the machine.

7. WASTE PUMPOUT AND AUXILIARY WATER

PUMP SWITCH

This four-position switch is for activating the
waste pumpout device. It also serves to activate
the fresh water transfer pump. For turning on
pumps, rotate clockwise. For turning off pumps,
rotate counter clockwise.






8. SOLUTION PUMP SWITCH

This switch serves to energize the magnetic
clutch to turn the water pump on or off. Turn
clockwise for activating the pump and counter
clockwise for deactivating the pump.


9. THROTTLE

This serves to set the speed of the engine by
rotating the throttle knob counterclockwise to
increase, clockwise to decrease. The cable has
a collar lock, which serves to lock in a given
speed.


10. KEY SWITCH

The key switch controls the power for the
machine. To turn the machine on, rotate the
key counterclockwise to energize the glow plugs
and hold. This will illuminate the green glow
plug lamp. When the glow plug lamp goes out
the engine is ready to start. Turn solution pump
switch counterclockwise to override and hold.
Turn key switch clockwise until engine starts
and release. Wait 5 seconds then release
override switch. To stop engine rotate key to
OFF position.


11. HOUR METER


The hour meter records the number of hours the
unit has run. This serves as a time recorder for
servicing the machine.

12. CIRCUIT BREAKERS

These serve to protect the circuits from
electrical spike and over loads and protects
wires from damage and fire.


13. SOLUTION TEMPERATURE CONTROL

VALVE

This valve enables additional heat exchangers
to contribute more heat to the system if
necessary. By rotating the lever to the right it
adds more heat, by rotating to the left it removes
heat.









Advertising