2 preventative maintenance – Sterlco SGBD Series Batch Gravimetric Blenders User Manual
Page 71

BLN1-600
Chapter 5: Maintenance
71 of 110
5-2 Preventative Maintenance
Our blenders need periodic maintenance to provide long dependable service. Check these
elements regularly:
• Check functionality of safety circuit daily.
• Maintain proper air pressure and drain water from trap assembly on regulator – as
required.
• Periodically lubricate slide gate rails.
Always remove plug and disconnect power before servicing blender.
Always read operating manual before operating or servicing blender.
Gear box on BD, SGBD, CSG-4000/6000 and RAM units with right angle gear boxes:
• Change oil after initial break-in period of 250 hours of operation and at 2500 hours of
operation or 6 month intervals after break-in period.
• Recommended oil is Mobil SHC 634 Synthetic oil. 5 gal P/N: OIL0041
Part Description
Part Number
Oil Capacity
(Fluid Ounces)
4000/6000 Right
Angle Reducer
51415
13
160.00280.00
11
RAM
51183
4