When running conduit whips to the 2016-C unit, make sure
that whips are routed away from hot piping.
Check the unit nameplate for correct voltage and amperage
before making electrical connections!
!
DANGER
Improper electrical connections can
damage the unit and cause serious
operator injury or death!
Make sure that all electrical
connections are made by a qualified
electrician, and that all connections
are tight.
Make all electrical supply connections at the front of the unit. An
access panel covers all electrical connections. Run electrical
connections to the supply terminals from either side of the unit.
Make sure that all three phases are wired correctly. The pump runs
backwards if not wired properly.