Chapter 4: operation, 1 start-up, 2 operation procedures – Sterlco BP800 Series Granulators User Manual

Page 21

Advertising
background image

800 Series beside-the-press

Chapter 4: Operation

21 of 43

Chapter 4: Operation

4-1 Start-up

Pre-operational Checklist

To ensure the granulator is ready for operation, perform the outlined tasks in the
following pre-operational checklist. All electrical and mechanical machine elements
MUST be inspected and any defects MUST first be corrected.

ü

Make sure the operational manual has been read and followed.

ü

Make sure that all necessary personnel (granulator operators, cleanout,

maintenance, service personnel) have been fully trained on machine operation
and all machine safety mechanisms.

ü

Make sure sufficient location clearances have been allowed.

ü

Make sure the equipment is grounded in accordance with local codes and/or

Article 250 of the National Electric Code.

ü

Make sure all motors have been checked for proper rotation.

ü

Make sure all machine controls, push-buttons, and limit switch interlocks have

been checked for proper function.

ü

Make sure the cutting chamber has been checked for foreign matter.

ü

Make sure the drive components have been checked for alignment and tension.

ü

Make sure the machine is properly closed with all visible fasteners tight.

ü

Make sure all accessory components are electrically and mechanically connected

with proper support and fasteners tightened.

ü

Make sure electrical enclosure boxes are tightly closed and clamped shut.

ü

Make sure all personnel are clear of the machine.

4-2 Operation Procedures

The granulator can be operated in a vertical top-feed position or in a horizontal front-feed
position.

Before starting the granulator, always check for and remove tools or any other objects
placed on the granulator. Turn the Power disconnect switch to ON, pull the Start button,
and release it when the motor has started.

It is normal for the motor not to start immediately, as the electronic system must check all
the micro switches before enabling start-up procedures. Wait for the electric motor to
reach normal rotating speed before feeding the granulator.

Advertising