14

Page

-DIPswitch settings for Vent length-

4" venting

Vent length

240 Indoor (T-H3J-DV)

340 Indoor (T-H3S-DV)

540 Indoor (T-H3-DV)

(Upper bank of DIPswitches)

5 to 50 ft

(DEFAULT)

No. 6 : ON

No. 7 : OFF

No. 3 : ON

No. 4 : OFF

51 to 100 ft

No. 6 : OFF

No. 7 : OFF

No. 3 : OFF

No. 4 : OFF

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8 9 10

OFF

ON 1 2 3 4 5 6 7 8 9 10

3" venting

Vent length

240 Indoor (T-H3J-DV)

340 Indoor (T-H3S-DV)

540 Indoor (T-H3-DV)

(Upper bank of DIPswitches)

5 to 20 ft

(DEFAULT)

No. 6 : ON

No. 7 : OFF

No. 3 : ON

No. 4 : OFF

21 to 40 ft

No. 6 : OFF

No. 7 : OFF

No. 3 : OFF

No. 4 : OFF

41 to 70 ft

No. 6 : ON

No. 7 : ON

No. 3 : ON

No. 4 : ON

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8 9 10

OFF

ON 1 2 3 4 5 6 7 8 9 10

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8 9 10

Set DIPswitches shown in the tables below depending on the vent length.

3" venting

Vent length

240 Indoor (T-H3J-DV)

340 Indoor (T-H3S-DV)

540 Indoor (T-H3-DV)

(Upper bank of DIPswitches)

5 to 45 ft

(DEFAULT)

No. 6 : ON

No. 7 : OFF

No. 3 : ON

No. 4 : OFF

46 to 70 ft

No. 6 : OFF

No. 7 : OFF

No. 3 : OFF

No. 4 : OFF

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8

OFF

ON 1 2 3 4 5 6 7 8 9 10

OFF

ON 1 2 3 4 5 6 7 8 9 10

Set DIPswitches shown in the table below depending on the vent length.

<Single pipe with room-air intake installation>

<Two-pipe, direct-vent installation>

Installation