Specifications – Takagi T-H3M-IN/OS User Manual

Page 4

Advertising
background image

4

Page

Installation Manual

Specifications

SPECIFICATIONS

*40 psi (027 MPa) or above is recommended for maximum flow

** The Manifold Pressure is the factory setting and should not need adjustment

NOTE:

• Check the rating plate to ensure this product matches your specifications

• In accordance with ANSI Z21103, CO emission does not exceed 400 PPM for normal input

• The manufacturer reserves the right to discontinue, or change at any time, specifications or designs

without notice and without incurring obligation.

Model

140

Indoor

(T-H3M-DV)

140

Outdoor

(T-H3M-OS)

Natural Gas Input

(Operating Range)

BTU/h

Min: 15,000

Max: 120,000

Propane Input

(Operating Range)

BTU/h

Min: 15,000

Max: 120,000

Gas Connection

1/2" NPT

Water Connection

3/4" NPT

Water Pressure*

psi

(MPa)

15 - 150 (01 - 10)

Natural gas

Inlet Pressure

inch WC

(kPa)

Min 50 (12)

Max 105 (26)

Propane

Inlet Pressure

inch WC

(kPa)

Min 80 (20)

Max 140 (35)

Manifold

Pressure**

Natural

Gas

inch WC

(Pa)

330

(820)

200

(500)

Propane

inch WC

(Pa)

300

(750)

160

(400)

Weight

lbs (kg)

58 (225)

58 (225)

Dimension

inch

H 21-3/4 x W 14 x D 9-1/4

H 552 x W 352 x D 236

mm

Ignition

Electric Ignition

Electric

Supply

VAC / Hz

120 / 60

Consump

tion

Operation

W / A

539 / 07

Standby

W / A

32 / 005

Freeze-

Protection

W / A

2239 / 194