Technical data – Timeguard TR 608 top2 User Manual

Page 23

Advertising
background image

23

GB

Technical data

• Operating voltage:

230 –240 V~, +10 %/-15 %

• Frequency:

50–60 Hz

• Power consumption:

ca. 0,4 W

• Standby min.:

ca. 0,4 W

• Switch output:

switching of choice of

external wires is permitted

• Contact:

two way switch

• Gap:

<3 mm (µ)

• Contact material:

AgSnO

2

• Max switching capacity: 16 A, 250 V~, cos ϕ = 1;

4 A, 250 V~, cos ϕ = 0,6

• Min. switching capacity: 10 mA/230 V AC

100 mA/12 V AC/DC

• Incandescent lamp load: 1000 W
• Halogen lamp load:

1000 W

• Fluorescent lamp load: uncorrected,

series corrected 1000 VA

parallel correction 120 W (18µF)

• Compact fluorescent lamps: 40 W
• LED lamps:

<2 W output, max. connec-

tion total of 10 W,

>2 W < 8 W output, max.

connection total of 25 W

• Permissible ambient temperature:

–25 °C ... +55 °C

• Protection class:

II in accordance with

EN 60730-1 subject to

designated installation

• Protection rating: IP 20 nach EN 60529
• Time accuracy:

≤ ±0,5 s/day at 25 °C

• Power reserve:

10 years (lithium cell)

at +20 °C

• Pollution degree:

2

• Rated impulse withstand voltage: 4 kV
• Max. switching cycles with 16 A
resistive load:

50,000

Advertising