General RCD Specifications

Voltage:

230V AC 50Hz

Max Current:

Fully complies with the current rating
required by BS1363

Rated Trip Current:

30mA

RCD Type:

Double Pole, suitable for
2 and 3 wire applications

Breaking Capacity:

250A (Earth leakage)

Through Fault Withstand:

1500A

Operating Temperature Range:

-5° to 40°C

Trip Speed:

Less than 40msec at 150mA
residual current

Fully Complies With:

BS7288 & BS1363

Minimum Box Depth Required:

25mm

Fixed Cable Capacity:

1 x 8mm

2

or 2 x 4mm

2

or 3 x 2.5mm

2

Flexible Cable Capacity:

10.5mm diameter maximum

(TFP10WL only)

d

r

e

e

y