3 year guarantee, Specifi cations, Temperature adjustment setting – Timeguard TPT88 User Manual
Page 11: Probe & mains supply check

10
3 Year Guarantee
In the unlikely event of this product becoming faulty due to
defective material or manufacture within 3 years of the date
of purchase, please return it to your supplier in the fi rst year
with proof of purchase and it will be replaced free of charge.
For the second and third years or any diffi culty in the fi rst year
telephone the helpline on 020 8450 0515.
Specifi cations
Operating temp:
-10°C to 40°C
Operating voltage:
220 – 240V AC 50Hz
Switching capability:
16A resistive 3A inductive
Temp probe fl ying lead:
4m length
Temp control range:
6°C to 30°C
Temperature accuracy:
±1°C (at 20°C)
Control type:
Normally open, voltage free
EC directives:
Conforms to 73/23/EEC
and
89/336/EEC
Dimensions (mm):
84 (H) x 84 (W) x 27 (D)
Temperature adjustment setting
If the TIME/COPY key is pressed and then MODE/NEXT key is
pressed then SU:0 or Ad:0 will display. Press the PROG button
to return to normal operation.
It is recommended that this function is not used without
consulting the Help Line.
Probe & mains Supply Check
The unit checks that the temperature probe is connected and
is not short circuit. If this is not the case then the ‘!’ symbol
shows on the display, the installer should then check the
connections. The ‘!’ symbol also indicates loss of mains supply.
TPT88_Instructs_Art_TG_1.5.indd 11
TPT88_Instructs_Art_TG_1.5.indd 11
19/9/06 09:53:54
19/9/06 09:53:54