Trio Motion Technology MC206x User Manual

Page 7

Advertising
background image

Ensure that:

1. The shield pin is grounded as close to

the MC206X as possible.

2. 0V, V- and E- connections are NOT used

for terminating screens.

3. Pin 5 of Encoder/Stepper plug is

connected to 0V on drive.

4. Encoder cable screen is clamped to 9

way D shell.

5. MC206X 24V supply has common 0V with

the drive(s)

When wiring MC206X Stepper outputs to

a differential input stepper drive, use the

0V and shield connections shown for the

encoder. The stepper drive must have its

common 0V connected to the MC206X 24V

return. (24V -)

Follow the wiring instructions for the daughter board that is

installed. In addition, because the daughter board front panel is

fitted within the MC206X plastic case, a separate shield ground wire

should be connected to all screened cables. This includes all cables

terminated with a D-type multi-pin connector.

GROUNDING AND

SHIELDING

USE OF

DAUGHTER

BOARD

* Encoder input 0V MUST be connected to pin 5

!