UEi Test Instruments RLD15 User Manual

Rld15, Warning, Features specifications

Advertising
background image

1-800-547-5740 • Fax: (503) 643-6322

www.ueitest.com

email: [email protected]

AG

EN

T

:R

ef

rig

er

an

tL

ea

k

De

te

ct

or

INSTRUCTION MANUAL

Low

Battery

LO NORM HI

Certified J2791

Mute

Sens.

RLD15

Display # Leak Size

(oz/yr)

1-3 < 0.1
4-6 0.1 to 0.5
7-9 > 0.5

8

LEAK SIZE

REFRIGERANT DETECTOR

RLD15

INTRODUCTION

The AGENT RLD15 features a long life

heated sensor technology that is designed to
detect the more current and difficult HFC
refrigerants such as R134a, R410A, R404A,
R407C, in additiion to all HCFC (R22) and CFC
(R12) refrigerants including SNAP approved
hydrocarbon blends.

GETTING STARTED

LEAK SIZE INDICATOR

The digital leak size indicator remains off

until a leak is detected, a number from 1 - 9
will be displayed for all HFC and HCFC refriger-
ants. Regardless of the sensitivity settings.

The number will increase or decrease

depending on the amount of refrigerant
sensed. The maximum value will be displayed
once the leak source has been located.

SENSITIVITY LEVEL

LOW BATTERY INDICATOR

Replace batteries when flashing

AUDIO MUTE FUNCTION

Maximum # Displayed

1-3
4-6
7-9

Leak Size (oz/yr)

< 0.1

0.1 - 0.5

> 0.5

LEAK TEST VIAL

The Leak detector comes with a Leak Test

Vial that allows the user to make sure the
detector is performing properly. To test: Turn
the detector on and allow the unit to warm-up.

NOTE: Always remember to

replace plastic seal cap after leak
test is completed. Replace Test
Vial when the blue color is no
longer visible.

3/8” or Less

1. Remove Seal Cap

4. Replace Seal Cap

3. The beep rate should
increase and the Digital
Leak Size Indicator
should display a number
from 4 - 6 indicating that
the sensor and electron-
ics are working properly

2. Place Sensor tip close to

open vile.

FILTER REPLACEMENT

1. Replace Filter: Unscrew sensor tip as

shown to replace filter. Replace filter
whenever it becomes visibly dirty or every
2 to 3 months depending on use.

SENSOR REPLACEMENT

1.) Remove sensor by unscrewing sensor tip
and pulling out the socket.

2.) Install the new sensor by aligning the mark
on the sensor cover with that on the probe and
pressing together.

WARNING

DO NOT TWIST OR FORCE THE

SENSOR INTO THE SOCKET.

Misalignment can damage the sensor pins.

AA

AA

AA

AA

FEATURES

SPECIFICATIONS

Model #

Name

Sensitivity

Sensor Life

Response Time

Power Supply

Battery Life

Warm-Up Time

Probe Length

Numerical Display

Weight, lbs

Warranty

RLD15

AGENT 1

.05 oz/yr R134a

.025 oz/yr R22

> 300 Hours

≤ 1sec

4 AA Alkaline

8 Hrs. Continuous

<20 Seconds

17 inches

7 Segment Digital (1-9)

1.5 Lbs

3yr (Includes Sensor)

Cross Sensitivity to Automotive Chemicals

Some Automotive solvents and chemicals

have similar hydrocarbon properties as R134a
and may elicit a positive response (< 30 seconds)
from the AGENT. Before leak detecting, clean
up any chemicals in the list below that elicit a
response.

Dextron Transmission Fluid heated to 160˚F

Quaker State motor oil heated to 160˚F

Rain-X Windshield wash fluid

Ford silicone lubricant

Ford Gasket adhesive (when wet)

Ford rust inhibitor (when wet)

Loctite Natural Blue Degreaser (undiluted)

Ford brake parts cleaner (when wet)
Ford silicone rubber (when uncured)

Motorcraft antifreeze heated to 160˚F

Gunk liquid wrench (when wet)

Ford spot remover (when wet)

Ford pumice lotion (with mineral solvent)

Ford motorcraft brake fluid

Ford carburetor cleaner (when wet)

Low

Battery

LO NORM HI

Certified J2791

Mute

Sens.

RLD15

Display # Leak Size

(oz/yr)

1-3 < 0.1

4-6 0.1 to 0.5

7-9 > 0.5

8

LEAK SIZE

REFRIGERANT DETECTOR

Low

Battery

LO NORM HI

Certified J2791

Mute

Sens.

RLD15

Display # Leak Size

(oz/yr)

1-3 < 0.1
4-6 0.1 to 0.5
7-9 > 0.5

8

LEAK SIZE

REFRIGERANT DETECTOR

Mute

Sens.

Display # Leak Size

(oz/yr)

1-3

< 0.1

4-6

0.1 to 0.5

7-9

> 0.5

8

LEAK SIZE

Mute

Sens.

Display # Leak Size

(oz/yr)

1-3

< 0.1

4-6

0.1 to 0.5

7-9

> 0.5

8

LEAK SIZE

LO NORM HI

PLEASE

RECYCLE

LIMITED WARRANTY

RLD15

The AGENT is warranted to be free from defects in

materials and workmanship for a period of three years
from the date of purchase. If within the warranty period
your instrument should become inoperative from such
defects, the unit will be repaired or replaced at UEi’s
option. This warranty covers normal use and does not
cover damage which occurs in shipment or failure which
results from alteration, tampering, accident, misuse,
abuse, neglect or improper maintenance. Batteries and
consequential damage resulting from failed batteries are
not covered by warranty.

Any implied warranties, including but not limited

to implied warranties of merchantability and fitness for
a particular purpose, are limited to the express
warranty. UEi shall not be liable for loss of use of the
instrument or other incidental or consequential dam-
ages, expenses, or economic loss, or for any claim or
claims for such damage, expenses or economic loss.
A purchase receipt or other proof of original purchase
date will be required before warranty repairs will be
rendered. Instruments out of warranty will be repaired
(when repairable) for a service charge. Return the unit
postage paid and insured to:

UEi

8030 SW Nimbus Ave.

Beaverton, OR 97008

Copyright © 2009 UEi

RLD15-MAN 3/09

Mute

Sens.

Display # Leak Size

(oz/yr)

1-3

< 0.1

4-6

0.1 to 0.5

7-9

> 0.5

8

LEAK SIZE

LEAK SIZE

1. TURN ON:

Press
Power Button

1. Press Mute

Button to
Mute Speaker.

1. Press Sens.

Button to
Change / Scroll
Sensitivity
Levels.
(Indicated
By LED)

2. WARM UP:

Allow 20 sec.
to warm up.

(Indicator will
blink and alarm
will beep)

LO NORM HI

3. READY:

When the flashing
“8” stops and the
green sensitivity
indicator LED
turns on

LEAK SIZE

Approximate Size Indications

BATTERY REPLACEMENT:

1. Remove battery cover on back of

instrument. (Fig1)

2. Replace batteries (4 AA) with correct

polarity.

(Fig1)

Replace w/
New Filter

Remove
Old (Dirty) Filter

Unscrew
Sensor Tip

Unscrew
Sensor Tip

Filter

Pull Straight Apart
DO NOT TWIST!

1.)

2.)

Screw On
Sensor Tip

Filter

Push Straight Together
DO NOT TWIST!

DO

N

OT

TW

IS

T!

Align New Sensor With Tip

And Push Straight On.