Troubleshooting, Specifications – UEi Test Instruments DL99B User Manual

Page 7

Advertising
background image

Troubleshooting

NOTE: This unit contains no user serviceable parts beyond those listed in
table above. In the event your instrument is physically damaged or does not
function properly after taking the listed action, please return the instrument
to UEi following the warranty and service instructions.

Specifications

Measurement limits

General Specifications

Electrical Specifications

*1000 V AC and Dc scales autorange from 400 to 1000 when greater than
400 volts are applied.

If I see this

I should check for

Then take this

malfunction

corrective action

Debris on switch controls

Move switch through all

functions 3 to 4 times

Instrument does not

Battery voltage

Replace low battery

turn on

Rotary switch position

Ensure switch moves freely

and is set to a

measurement position

Instrument turns on but

Peak Hold button pressed

Look for PEAK or HOLD

LCD indicates some

icons displayed on the LCD

unreasonable or

HOLD button pressed

Turn off one or both buttons

unchanging value

Short test leads together -

A value appears

Stray voltage or EMF fields

If a value near 000 appears,

on screen with no

instrument is OK

input applied

Move meter and leads

away from devices that

create electrical fields

Defective test leads

Short test leads together

in the 400 ohm scale -

Expect less than .5Ω

A known value is not

PEAK or HOLD buttons pressed

Turn off one or both

displayed on the LCD

buttons (check for icons

when measured

on LCD)

Bad test lead connections

Ensure test leads are fully

inserted and free of

corrosion or dirt

DC Amps not zeroed

Move meter away from

power source and press

DC or ZERO for 2 seconds

Battery voltage

Replace low battery

Jaws are not closed tight

Clean top and bottom

mating surfaces of

clamp jaws

Meter reading is

Rotary selector knob is offset

Ensure knob is firmly

unstable

placed in switch position

Bad test lead connection

Ensure there is no

insulating material, dirt

or debris at contact points

No audible tone with

Improper selector position

Tone sounds only in

near zero resistance

continuity mode -

value

Place selector in

position

Amps reading does

Proper switch position

Ensure switch is in proper

not work

AC or DC amps position

(A AC or A DC)

DL99B-MAN

P. 6

AC Amperage

1000 Amps

DC Amperage

1000 Amps

AC Voltage

1000 Volts

DC Voltage

1000 Volts

Ohms

400 Kilohms

Continuity

< 40 ohms

Size H x W x L, in (mm)

9.20” x 3.42” x 1.77”
(234 x 87 x 45)

Maximum Jaw Opening

1.25” (32 mm)

Storage Temperature

-4˚ to 140˚F
(-20˚ to 60˚C)

Operating Temperature

32˚ to 113˚F
(0˚ to 45˚C)

Relative Humidity

0% to 80% RH

(Storage and Use)
Weight (approximate)

14.8 oz (420 g)

Electrical Certification Standards:

IEC 1010-1 CAT III 600 Volts

1000 Amps AC/DC

CSA C22.2 No. 1010.1

ISA S 82,01

Battery Type

9V, NEDA 1604, 6F22 or 006P

Function

Range

Resolution

Accuracy

AC Amps @

400 A

0.1 A

±(2% + 5 digits)

(50 Hz to 450 Hz)

1000 A

1 A

DC Amps

400 A

0.1 A

1000 A

1 A

±(1.5% + 3 digits)

AC Volts*

400 V

0.1 V

±(1.9% + 3 digits)

(50 Hz to 400 Hz)

1000 V

1 V

DC Volts*

400 mV

0.1 mV

±(1.0% + 2 digits)

400 V

0.1 V

1000 V

1 V

Ohms

400

Ω

0.1 Ω

±(1.0% + 2 digits)

40 K

Ω

0.01 KΩ

Continuity

400 Ω

600 VΩ

Tone sounds @ < 40 Ω