Installation – Filter Housing Cabinet


Ultravation RAD Photronic Air Cleaning Systems is
designed to be installed adjacent to the air handler.
The air cleaner is also designed to be internally
reversible with the airflow direction. They must be
installed in an area of the duct that precedes the blower
compartment. In this location, the blower motor and
internal components will be kept clean. This increases
air handler component life, improves system efficiency,
and reduces maintenance costs.

The Ultravation Right Angle Design Air Cleaner has
been designed for use in conjunction with virtually any
HVAC system.

Do not install this unit in the supply duct.

Be sure to plan adequate space for filter replacement.

Before installation is complete, seal all joints and
seams with duct tape or caulking.

Installation of Electronic Power Supply:

1. Determine the desired airflow path for installation
and determine available room for lamp replacement.
(This will determine the placement of the electrical
enclosure on the units – remove the knockout from the
filter cabinet)

2. Remove the cover from the electrical box.

3. Line up the lamp hole in the electrical enclosure with
the knockout on the filter cabinet and screw electrical
housing into place with provided hardware.

4. Install the twin tube (white in color) photocatalytic
lamp. When installed it is parallel to the Mesh filter.

5. The photocatalytic lamp clips into the socket with
diagonal pressure then seat back into place. (See
Illustration on page 6)

6. See instructions on setting the indicator light on
models utilizing UVC lamps. (page 6).

7. Reinstall the electrical cover.

* When the 24VAC power supply unit is purchased it
comes with a 100VA 24VAC secondary transformer to
be dedicated to the Ultravation equipment.

Electronics can be located

on either side or the back

(recommended)

depending on access for

Installation requirements:


This unit is designed to be powered up constantly
and should not cycle on and off with a blower motor.

Unit must be installed either; within 6 feet of a 120 power
outlet, or hardwired per local and state electrical code
(Range 120-240VAC).

There must be at least 16 inches above the unit for
UVA lamp replacement.

There must be minimum 26 inches in front of the door for
filter replacement.