background image

CF108-SS REV05

TRANSFORMER CHART

WIRING DIAGRAM (CF108-4T/CF108-4TWG)

CF108

VIOLET

WHITE LEAD

GRAY LEAD

COMMON

8 Ω

BLUE

GREEN

YELLOW

ORANGE

RED

BROWN

COMMON

+

-

WIRING DIAGRAM (CF108-4T 71/CF108-4TWG-71)

YELLOW

0.5 dB

1.0 dB

8 Ω

ORANGE

RED

BROWN

COMMON

BLACK/WHITE

BLACK LEAD

COMMON

+

-

Utility 4 W

Utility 8 W

25 V

70 V

100 V

Transformer

Transformer

Primary Tap

Primary Tap

Primary Tap

(T404-27)

(T408-27)

Color Code

Color Code

Color Code

Primary Taps

Primary Taps

4.0 W

8.0 W

Brown

Yellow

Green

2.0 W

4.0 W

Red

Green

Blue

1.0 W

2.0 W

Orange

Blue

Violet

0.5 W

1.0 W

Yellow

Violet

N/A

Primary Common

Black

CF108-71

Premium 8 W(T508-71) /
4 W (T504-71) Transformer
Primary Tap Color Code

Black

Brown

Red

Orange

Yellow

70 V Primary Tap
4 W(T504-71)

Common

4.0 W

2.0 W

1.0 W

0.5 W

100 V Primary Tap
4 W(T504-71)

Common

N/A

4.0 W

2.0 W

1.0 W