86

-EN

Foot Brake Lead / Parking Brake Lead Connection

Connection Diagram of SPST Switch (Sold Separately)

(If the ACC power supply is not available)

• If your vehicle has no ACC power supply, add an SPST (Single-Pole, Single-Throw) switch (sold separately) and fuse (sold separately).
• The diagram and the fuse amperage shown above are in the case when IVA-W505 is used individually.
• If the switched power (ignition) lead of the IVA-W505 is connected directly to the positive (+) post of the vehicle’s battery, the IVA-W505 draws

some current (several hundred milliamperes) even when its switch is placed in the OFF position and the battery may be discharged.

IVA-W505

Parking brake switch

(Yellow/Black)

Foot brake lamp

Foot brake switch

Battery

Chassis

Foot brake lead

Parking brake lamp

Parking brake lead

Pinch

Connector
(sold separately)

Pinch

Connector
(sold separately)

(Yellow/Blue)

PARKING BRAKE

FOOT BRAKE

IVA-W505

(Red)

(Yellow)

SPST SW (Optional)

FUSE (5A)
(Optional)

FUSE (20A)
(Optional)

Battery

IGNITION

BATTERY

To prevent external noise from entering the audio system.

• Locate the unit and route the leads at least 10 cm away from the car harness.
• Keep the battery power leads as far away from other leads as possible.
• Connect the ground lead securely to a bare metal spot (remove any paint, dirt or grease if necessary) of the car chassis.
• If you add an optional noise suppressor, connect it as far away from the unit as possible. Your Alpine dealer carries various

noise suppressors, contact them for further information.

• Your Alpine dealer knows best about noise prevention measures so consult your dealer for further information.