GETTING READY

— — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —

36

Replacing the needle

Replace the needle as described below. Use the
screwdriver and a needle that has been determined to
be straight according to the instructions in “Checking
the needle” (page 35).

a

Press

(Needle position button) once or

twice to raise the needle.

a Needle position button

b

Turn off the machine.

CAUTION

c

Lower the presser foot lever.

a Presser foot lever

d

Place fabric or paper under the embroidery
foot to cover the hole in the needle plate.

Note

z Before replacing the needle, cover the hole

in the needle plate with fabric or paper to
prevent the needle from falling into the
machine.

e

Hold the needle with your left hand, and then
use a screwdriver to turn the needle clamp
screw toward you (counterclockwise) to
remove the needle.

a Screwdriver
b Needle clamp screw

• Do not apply a strong force when loosening

or tightening the needle clamp screw,
otherwise certain parts of the machine may
be damaged.

● Before replacing the needle, be sure to

turn off the machine, otherwise injuries
may occur if

(Start/stop button) is

accidentally pressed and the machine
starts embroidering.