1 equipment rack guidelines, 3 sfp mini gbic ports, 4 installing the optional external power supply – Asante Technologies IC36240 Series User Manual

Page 12

Advertising
background image

5. Place the switch in the equipment rack.

6. Secure the switch by securing its mounting brackets onto the equipment rack with the appropriate screws

(supplied).

Important: Make sure the switch is supported until all the mounting screws for each bracket are secured to the
equipment rack. Failure to do so could cause the switch to fall, which may result in personal injury or damage to the
switch.

2.2.1 Equipment Rack Guidelines

Use the following guidelines to ensure that the switch will fit safely within the equipment rack:

Size: 17.5 x 12.7 x 1.8 inches (440 x 234 x 45 mm)

Ventilation: Ensure that the rack is installed in a room in which the temperature remains below 104° F (40° C). Be
sure that no obstructions, such as other equipment or cables, block airflow to or from the vents of the switch

Clearance: In addition to providing clearance for ventilation, ensure that adequate clearance for servicing the
switch from the front exists

2.3 SFP Mini GBIC Ports

The GBIC Interface is the industry standard for Gigabit Ethernet Interfaces.

The Gigabit SFP module inserts into the Mini GBIC port to create a new Gigabit port. The hot-swapping feature on
the IntraCore IC36240 lets you install and replace the SFP transceivers while the system is operating; you do not
need to disable the software or shut down the system power.

To install the module, do the following:

1. Insert the transceiver with the optical connector facing outward and the slot connector facing down. The module

is keyed to help establish the correct position.

2. Slide the SFP transceiver into the slot until it clicks into place.

3. Remove the module’s rubber port cap.

4. Connect the cable to the Gigabit SFP module’s port.

Caution: When replacing a SFP transceiver you must always disconnect the network cable before removing a
transceiver.

2.4 Installing the Optional External Power Supply

The IntraCore IC36240 can be equipped with an optional 12 VDC external power supply (part number 52-10029-00).
When installed, the external power supply is in standby mode. Should the primary unit fail, the backup automatically
switches. In addition, an SNMP fault notice is sent.

12

Asante IntraCore IC36240

Setup Guide

Advertising