Agilent Technologies E8247C PSG CW User Manual

Page 101

Advertising
background image

Chapter 5

91

Dual Arbitrary Waveform Generator

Arbitrary (ARB) Waveform File Headers

2. Save the information in the

Current Inst. Settings

column to the file header:

Press

Save Setup To Header

.

The same settings are now displayed in both the

Saved Header Settings

column and the

Current

Inst. Settings

column. The settings in the

Saved Header Settings

column are the ones that

have been saved in the file header.

The following signal generator settings are saved to the file header:

32-Character Description:

A description entered for the header, such as a the waveform’s function (saved/edited
with the

Edit Description

key, see

Figure 5-2 on page 90

).

Sample Rate:

The ARB sample clock rate.

Runtime Scaling:

The Runtime scaling value. Runtime scaling is applied in real-time while the
waveform is playing. This setting can be changed only for files in the dual ARB player.

Marker 1...4 Polarity:

The marker polarity, positive or negative.

ALC Hold Routing:

Which marker, if any, implements the PSG’s ALC hold function.

The ALC hold function holds the ALC modulator at its current level when the marker
signal is low. When the marker signal goes high, the ALC hold function is
discontinued. If the RF Blank Routing function is selected, it automatically activates
the ALC hold for the same marker.

Alt Ampl. Routing:

Which marker, if any, triggers the PSG’s alternate amplitude feature when the marker
signal is low. When the marker signal goes high, the trigger is terminated disengaging
alternate amplitude. You must configure the alternate amplitude parameters, accessed
in the

Amplitude

hardkey menu.

RF Blank Routing:

Which marker, if any, implements the PSG’s RF blanking function when the marker
signal is low. Selecting RF blanking also implements ALC hold. When the marker
signal goes high, RF blanking is discontinued.

NOTE

All waveforms generated in the PSG have a marker on the first sample point. To see the desired
results from the three routing selections, you may need to select a range of sample (marker)
points. To set the marker points, use the

Set Marker on Range of Points

softkey in the

Marker Utilities

menu. Refer to

“To Place a Marker Across a Range of Points within a Waveform Segment” on

page 104

for more information.

I/Q Mod Filter:

The I/Q modulator filter setting. The modulator filter affects the I/Q signal modulated
onto the RF carrier.

I/Q Output Filter:

The I/Q output filter setting. The I/Q output filter is used for I/Q signals routed to the
rear panel I and Q outputs.

Mod Attenuation:

The I/Q modulator attenuation setting.

Advertising
This manual is related to the following products: