The procedures for mounting the camera to the ceiling using the indoor dome housing are
described below.
Before installing the camera, set the IP address and other network information on the camera
using the “VB Initial Setting Tool” on the Setup CD-ROM.
For details on how to operate the “VB Initial Setting Tool”, see “Operation Guide”.
If using an SD memory card, insert the SD memory card into the camera before installing (see
“Installation Guide” > “Using an SD Memory Card” included with the camera).

Important

Once the camera is installed to the ceiling, to insert and remove the SD memory card, the camera must
be removed from the ceiling and the ceiling bracket dismounted.

1

Determine an installation position for the camera and drill holes in the ceiling

Using the included template, line up the directon of the camera, determine the locations of
the backside ceiling bracket mounting holes (three) and the ceiling bracket holes, then drill
the holes ( 165 mm ( 6.50 in.)) into the ceiling.

Important

When mounting the indoor dome housing, be sure no shavings enter the dome.

2

Mount the camera to the ceiling bracket

Affix with four included fixing screw (M3).

3

Mount the dust cover to the ceiling bracket

Affix with three included fixing screw (M3).

4

Attach the backside ceiling brackets inside the ceiling

From the inside of the ceiling, insert the protrusions on the backside ceiling brackets through
the mounting holes drilled in step 1.

5

Temporarily tighten screws to the backside ceiling bracket

Temporarily tighten the three included ceiling bracket screws (M4) through the ceiling.

6

Secure the safety wire

Securely attach the safety wire to an anchor or structure. After securing one end of the safety wire
to the ceiling, secure the other end to the camera using the screw that is fastened to the camera.

7

Connect the LAN cable to the camera through the wiring hole

If AC Adapter PA-V17 (sold separately) or an external power supply is used, connect the
power connector to the camera. Connect cables to external device I/O terminals and audio
input/output terminals as necessary (see “Installation Guide” > “Connecting the Camera”
included with the camera.).

8

Mount the ceiling bracket on the ceiling

Position the ceiling bracket over the screws temporarily tightened in step 5, turn clockwise to
temporarily secure in place, and completely fasten the screws.

9

Attach the dome

Align the (O) mark on the dome with the (I) mark on the ceiling bracket, and turn clockwise
until the (I) mark on the dome aligns with the (I) mark on the ceiling bracket. This procedure
also aligns the ceiling bracket screw hole with the dome fixing screw hole.

10

Affix the dome

To prevent the dome from rotating, attach one dome fixing screw (M2).

11

Reboot the camera when the installation is complete

The camera position is initiated (see “Operation Guide” > “Setting Page” > “Maintenance”).

Note

While the LED is on, light may reflect inside the dome and be captured on video. If this happens, set the
LED setting to [Turn Off] (see “Operation Guide” > “LED Setting”).

9

8

6

4

2

3

5

7

10

Main Specifications

Model

DR41-C-VB/DR41-S-VB

Type

Clear/Smoked

Dimensions

( x H) 204 x 176 mm ( 8.03 x 6.93 in.) (Dome: R62 mm (R2.44 in.))

Weight

Approx. 765 g (1.687 lb.) (excluding camera)

Smoked (DR41-S-VB)
This dome is approximately 50% transparent.

Min. subject illumination

Day Mode (color)

0.8 lux (F1.6, shutter speed 1/30 sec., when smart shade control is off, 50IRE)

0.06 lux (F1.6, shutter speed 1/2 sec., when smart shade control is off, 50IRE)

0.02 lux (F1.6, shutter speed 1/2 sec., when smart shade control is on, 50IRE)

0.8 lux (F1.6, shutter speed 1/30 sec., when smart shade control is off)

0.2 lux (F1.6, shutter speed 1/8 sec., when smart shade control is off)

0.06 lux (F1.6, shutter speed 1/8 sec., when smart shade control is on)

Night Mode (monochrome)

0.04 lux (F1.6, shutter speed 1/30 sec., when smart shade control is off, 50IRE)

0.004 lux (F1.6, shutter speed 1/2 sec., when smart shade control is off, 50IRE)

0.002 lux (F1.6, shutter speed 1/2 sec., when smart shade control is on, 50IRE)

0.02 lux (F1.6, shutter speed 1/30 sec., when smart shade control is off)

0.004 lux (F1.6, shutter speed 1/8 sec., when smart shade control is off)

0.002 lux (F1.6, shutter speed 1/8 sec., when smart shade control is on)

External Dimensions

204 (8.03)

R62

(R2.44)

162 (6.38)

(Max. circumscribed

exterior dimension)

10 (0.39)

7( 0.28)

182 ( 7.17)

176 (6.93)

92 (3.62)

3- 4.6 (

0.18)

(ceiling mount holes)

120°

11

Safety wire

Secure to an

anchor or

structure

LAN cable

Ceiling

bracket

Backside

ceiling

bracket

Ceiling board

Dome

Camera

Fixing

screw

M3 x 3

(included)

Fixing

screw

M3 x 4

(included)

Ceiling bracket screw

M4 x 3

(included)

Unit: mm (in.)

Advertising
This manual is related to the following products: