Electric cooktop installation instructions, Hg a – Electrolux EW30CC55GS User Manual
Page 2
 
2
ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS
Figure 2 – COUNTERTOP CUTOUT OPENING
CAUTION
To eliminate the risk of burns or
fire	by	reaching	over	heated	surfaces,	cabinet	
storage	space	located	above	the	cooktop	should	
be	avoided.	If	cabinet	storage	is	provided,	risk	
can	be	reduced	by	installing	a	range	hood	that	
projects	horizontally	a	minimum	of	5"	(12.7	cm)	
beyond	the	bottom	of	the	cabinets.
Letters on this figure refer to chart on front page except for J, K & L.
I
H
G
A
Overhead Cabinet Should Not exceed a
Maximum Depth of 13" (33 cm)
30" (76.2 cm) Min.
Clearance Between the
Top of the Cooking
platform and the Bottom
of an Unprotected Wood
or Metal Cabinet.
24" (61 cm) Min. when
Bottom of Wood or Metal
Cabinet is protected by
Not Less Than 1/8" (0.3
cm) Flame Retardant
Millboard Covered With
Not Less Than No. 28
MGS Sheet Steel, 0.015"
(0.4 mm) Stainless
Steel, 0.024" (0.6 mm)
Aluminum or 0.020" (0.5
mm) Copper.
2 1/2" (6.4 cm) Min. From edge
of Cutout to Front edge of
Countertop
18"
(45.7 cm)
J
Min. From edge of
Cooktop to Nearest
Combustible Wall
(either Side of Unit).
12"
(30.5 cm)
10"
( 25.4 cm)
K
Min. Recommended
Distance Between Rear
edge of Cutout and
Nearest Combustible
Surface Above
Countertop
24"
(61 cm)
Install junction box at a
location which will be easy
to reach and that will not
interfere with the cooktop
installation. We suggest
12" (30.48cm) lower than
the countertop.
If a drawer is present
underneath, allow at least
10" (25.4cm) of clearance
below the countertop.
CAUTION
Never store
flammable products in the
drawer.
L
Min.
MODEL
J
K
L
30’’ (76.2 cm)
7½’’ (19.1 cm)
2’’ (5.1 cm)
30’’ (72.6 cm)
36’’ (91.4 cm)
7½’’ (19.1 cm)
2’’ (5.1 cm)
36’’ (91.4 cm)