Electrolux EI23BC30KS User Manual

Caution, Defrost specifications, Condenser fan motor

Advertising
background image

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT 37°/0°

CONTROL SETTING (2500++ CONTROL)

Variable Speed Compressor

65°F (18°C) Ambient

90°F (32°C) Ambient

Operating Time

32 to 40%

100%

Freezer Temperature

-6° to 6°F

-21° to -14°C

-6° to 6°F

-21° to -14°C

Refrigerator Temperature

33° to 46°F

0.5° to 8°C

33° to 46°F

0.5° to 8°C

Low Side Pressure
(cut-in)

5 to 12 psig

34 to 83 kPa

N/A

Low Side Pressure
(cut-out)

-2 to 2 psig

-14 to 14 kPa

-2 to 2 psig

-14 to 14 kPa

High Side Pressure

85 to 95 psig

586 to 655 kPa

120 to 135 psig

827 to 931 kPa

Wattage

40 to 55

60 to 70

Amps (running)

0.5 to 1.1

0.7 to 0.9

Base Voltage

115 vac (127 vac max)

DEFROST SPECIFICATIONS

Cabinet Size

Thermostat

Heater

Cut-in

Cut-

out

Watts

Ohms

23’ SD, 28’ SD, 23’ CD

25°F

(-4°C)

47°F

(8°C)

500

26

Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.

CONDENSER FAN MOTOR

Watts

RPM

Amps

3.1

(Energy Star, some models)

1100 CW

Opposite Shaft

0.03 Running

FREEZER ICE MAKER SPECIFICATIONS

Electrical

115 vac (127 vac max)

Thermostat

Opens at 48°F (9°C), Closes at 15°F (-9°C)

Heater Voltage

115 vac

FREEZER ICE MAKER CONNECTOR PLUG CONNECTIONS

Wire Number

Wire Color

Connects to:

1

Green / Yellow

Ground

2

Yellow

Water Valve

3

Black

Line

4

Light Blue

Neutral

CAUTION

All electrical parts and wiring must be shielded from torch flame. DO
NOT allow torch to touch insulation; it will char at 200°F and flash ignite
(burn) at 500°F. Excessive heat will distort the plastic liner.

SERVICE DATA SHEET

242199300

FREEZER ICE MAKER - AUTOMATIC DEFROST

BOTTOM FREEZER - R134a

System Diagnostic Mode

Activate:

Press

FZ UP and FZ DOWN temperature pads for up to 10 sec. simultaneously.

Press

FF UP to advance through tests.

Deactivate:

Press

FF UP for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of

inactivity.

Note: Silence alarm.

• Tests marked with “*” may not be applicable to this unit and will not be displayed in System Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for “on,” “off,” “CL,” “OP,” “SH,” “LO,” “HI” or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.

Test

To activate test:

Passing result

--

First Screen

--

All LED lights on UI illuminated

--

Second Screen

--

All segments on UI temperature displays illuminated

--

Third Screen

--

Blank UI display, no lights illuminated, no shadowing; “-” and “+”
blinking on FF display side to show location.

28

Dispenser Paddle

Press disp. paddle

“on” on UI when depressed; “off” when released

1*

Standard
Compressor

Press power on-off

Compressor running when “on”; stopped when “off”

2

Defrost Heater

Press power on-off

Defrost limit switch must be closed; verify “CL” in test 26.
Feel for heat from defrost heater when “on”.
If “OP” in test 26, heater will not activate.

3

FF Light

Press power on-off

With FF door open, FF lights on when “on”; off when “off”

8

Water Valve
(Dispenser)

Press power on-off

FF door must be closed.
Be prepared to collect water at dispenser.
Water dispenses when “on”; stops when “off”

9

FZ Light

Press power on-off

With FZ door open, FZ lights on when “on”, off when “off”

10

Auger Motor

Press power on-off

FF door must be closed.
Motor running when “on”; motor stopped when “off”

11

Cube/Crush
Solenoid

Press power on-off

FF door must be closed.

Do not leave solenoid in activated state.

Solenoid activated when “on”; deactivated when “off”

41*

Perfect Temp Drawer
(PTD)

Press power on-off

PTD UI illuminated when “on”, off when “off”

12*

VCC Condenser Fan

Press power on-off

Fan running when “on”; stopped when “off”

38*

VCC Compressor

Press power on-off

Compressor running when “on”; stopped when “off”

15

Evaporator Fan

Press power on-off

Fan running for

minimum of 10 sec. when “LO” or “HI”; stopped when

“off”. Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from “LO” to “HI”.

22

Damper

Press power on-off

With inspection mirror, observe damper open when “OP”; closed when “CL”

23

FF Door

Open/close FF door

“CL” on UI when door closed; “OP” when open

24

FZ Door

Open/close FZ door

“CL” on UI when door closed; “OP” when open

26

Defrost Limit Switch

Activates automatically

“CL” on UI when closed; “OP” when open

36

Ice Chute Door

Depress ice chute door
or press power on-off

“OP” on UI when manually opened; “CL” when closed. Or, using “power on-
off”, “OP” on UI when solenoid activated, “CL” when deactivated

29

FF Thermistor Mid-
level

Activates automatically

UI shows temperature sensed by FF thermistor; pass if within 10°F of
temperature measured with gauge at mid-level FF thermistor location.
“OP-” if open; “SH-” if short

30

FZ Thermistor

Activates automatically

UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
measured with gage at FZ thermistor location.
“OP” if open; “SH” if short

33

Ambient Thermistor
@ Main Board

Activates automatically

UI shows temperature sensed at main board; pass if within +20°F/-10°F of
temperature measured with gauge at main board location.
“OP” if open; “SH” if short

35*

FF Thermistor
Upper-Level

Activates automatically

UI shows temperature sensed by upper level FF thermistor; pass if within
10°F of temperature measured with gauge at upper-level FF thermistor loca-
tion. “OP¯” if open; “SH¯” if short

34*

Ambient Thermistor
@ UI

Activates automatically

UI shows temperature sensed at UI; pass if within +20°F/-10°F of tempera-
ture measured with gauge at UI location. “OP” if open; “SH” if short

0-

Firmware
Parameters

Press power on-off

Displays digit sequence; record

2-

Main Board
Firmware

Press power on-off

Displays digit sequence; record

4-

UI Firmware

Press power on-off

Displays digit sequence; record

IMPORTANT SAFETY NOTE

The information provided herein is designed to assist qualified repair personnel only. Untrained persons
should not attempt to make repairs due to the possibility of electrical shock. Disconnect power cord before
servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned to their original position
and properly secured.

Error Codes

Special Modes

Display

Interpretation

Mode

Display

Activate/Deactivate

(press for up to 10 sec. simultaneously)

FZ

FF

FZ

FF

--

OP

Open FF Thermistor

Manual Defrost

d

F

FF UP and FF DOWN / same to deactivate

OP

--

Open FZ Thermistor

Display / Showroom

77

77

FZ UP and FF DOWN / Power-on-Reset
(POR)

--

SH

Shorted FF Thermistor

Sabbath

Sb

Sb

FZ DOWN and FF UP / same to deactivate

SH

--

Shorted FZ Thermistor

System Diagnostic

No FF or FZ display,
all UI LEDs on.

FZ UP and FZ DOWN / FF UP to deactivate

SY

CF

UI to Main Control
Board communication
failure; on start up

Notes:
• Always check for pin back-outs, pinched or damaged wires before replacing components.
• Determine whether failure is caused by the component, main control board or wiring.

Contact TID before replacing main control board.

• Refer to Service Manual for additional information.

SY

CE

UI Main Control Board
communication error;
after a period in operation

SY

EF

Evaporator Fan Failure

FREEZER ICE MAKER INFORMATION

(Where Applicable)

Test Cycling: Remove cover by inserting screwdriver in notch at bottom and pry-
ing cover from housing. Use screwdriver to rotate motor gear counterclockwise until
holding switch circuit is completed. All components of ice maker should function to
complete the cycle.

Water Fill Volume: The water fill adjustment screw will change the fill time.
One full turn is equal to 20cc (.68 oz.). The correct fill is 102 to 130cc (3.4 to
4.3 oz.). When a water valve is replaced, the fill volume must be checked.

TU

R

N

Mounting
Plate
Screws

Mounting
Plate
Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION.

POWER

ICE MAKER

I

CE MAKER

ICE MAKER

WATER VALVE

LINE

THERMAL

CUT-OUT

HOLD

SWITCH

THERMOSTAT

SHUTOFF

SWITCH

WATER FILL

SWITCH

MOLD HEATER

MOLD

MOUNTING

PLATE

165 WATTS

MOTOR

NEUTRAL

BL

K

BLK

BLK

BLU

C

C

C

NO

NO

NO

NC

NC

NC

YELLOW

BRN

RED

GRN / YEL

RED

RED

LT. BLUE

P-3

P-1

P-2

P-4

ICE MAKER

LT. BLUE