service data sheet

241958200

reFriGeratOr draWers - r134a

impOrtant saFety nOte

The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing this appliance.
impOrtant
If any green grounding wires are removed during servicing,
they must be returned to their original position and properly
secured.

cautiOn

all electrical parts and wiring must be shielded from torch
flame. dO nOt allow torch to touch insulation; it will char
at 200°F and flash ignite (burn) at 500°F. excessive heat will
distort the plastic liner.

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS

AT MID-POINT CONTROL SETTING

type a with run/start
capacitor

65°F (18°c) ambient

90°F (32°c) ambient

Operating Time

N/A

30 to 50%

Temperature

34º F to 45º F

34º F to 45º F

Low Side Pressure (cut-in)

30 to 45 psig

208 to 310 kPa

30 to 45 psig

208 to 310 kPa

Low Side Pressure (cut-out)

-2 to 4 psig

-14 to 28 kPa

-2 to 4 psig

-14 to 28 kPa

High Side Pressure
(last 1/3 cycle)

90 to 120 psig

621 to 827 kPa

130 to 175 psig

896 to 1207 kPa

Wattage (last 1/3 cycle)

85 to 125

85 to 125

Amps (running)

.75 to 1.2

.75 to 1.2

Base Voltage

115 vac (127 vac max)

cOndenser Fan mOtOr

Watts

rpm

amps

3.1

1100 CW Opposite Shaft

0.03 Running

evapOratOr Fan mOtOr

1.7 each

9000

.02 each

Width

Height

Depth

23

13

/

16

inch

34-35 inches

26

3

/

4

inch

unit dimensions

nOte

Your Electrolux refrigerator drawers has been designed for

built-in installation. Your refrigerator drawers do not require

additional air space for top, sides or rear. The front grille must

nOt be obstructed.

To ease unit installation and removal, it is recommended that

the cabinet rough opening dimensions be increased by at least

¼ inch over the dimensions given for your unit.

impOrtant: pLease return this sheet tO
it’s OriGinaL LOcatiOn.

WarninG

double drawer refrigerator drawers are designed to be
built-in only. they can not be used for free-standing.
all screws supplied with the anti-tip Kit are for mounting
the bracket directly to wall studs. these screws will not
work if used with sheetrock (dry wall) or anything other
than wall studs.

Advertising