PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT

CONTROL SETTING

Capacitor Run or
Induction Run

70°F (21°C) Ambient

90°F (32°C) Ambient

Operating Time

40 to 50%

55 to 65%

Freezer Temperature

-3° to 3° F

-19° to -16° C

-3° to 3° F

-19° to -16° C

Low Side Pressure
(cut-in)

6 to 12 psig

41 to 83 kPa

6 to 12 psig

41 to 83 kPa

Low Side Pressure
(cut-out)

-1 to 3 psig

-4 to 21 kPa

-1 to 3 psig

-4 to 21 kPa

High Side Pressure
(last 1/3 cycle)

85 to 100 psig

575 to 670 kPa

120 to 135 psig

810 to 910 kPa

Wattage (last 1/3 cycle)

100 to 120

110 to 130

Amps (running)

.9 to 1.1

1.0 to 1.2

Base Voltage

115 vac (127 vac max)

DEFROST SPECIFICATIONS

Cabinet Size

Thermostat

Heater

Cut-in

Cut-out

Watts

Ohms

19’

21° F (-6° C)

42° F (6° C)

550

24

Electronic Timer - Defrost 30 minutes every 12 hours of compressor run time.

CONDENSER FAN MOTOR

Watts

RPM

Amps

2.3

1100 CW Opposite Shaft

0.13 Running

ICE MAKER SPECIFICATIONS

Electrical

115 vac (127 vac max) 60 Hertz

Thermostat

Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
Models with orange wire close at 8.96° F (-12.8° C)

Heater Wattage

165

ICE MAKER CONNECTOR PLUG CONNECTIONS

Wire Number

Wire Color

Connects to:

1

Green/Yellow

Ground

2

Yellow

Water Valve

3

Black

Line

4

Light Blue

Neutral

IMPORTANT: PLEASE RETURN THIS SHEET TO IT’S
ORIGINAL LOCATION

ICE MAKER INFORMATION

Test Cycling

Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. Use screwdriver to rotate motor gear
counterclockwise until holding switch circuit is completed. All
components of ice maker should function to complete the cycle.

TUR

N

Mounting

Plate
Screws

Mounting

Plate

Screw

Motor
Gear

Timing

Gear

Water Fill
Adjustment

Water Fill Volume

The water fill adjustment
screw will change the
fill time. One full turn is
equal to 20cc (.68 oz.).
The correct fill is 95 to
105cc (3.2 to 3.6 oz.).
When a water valve is
replaced, the fill volume
must be checked.

SERVICE DATA SHEET - 297299800

STANDARD - AUTOMATIC DEFROST FREEZER

MODELS (

R134a)

IMPORTANT SAFETy NOTICE

The information provided herein is designed to assist qualified
repair personnel only. Untrained persons should not attempt to
make repairs due to the possibility of electrical shock. Disconnect
power cord before servicing.

IMPORTANT

If any green grounding wires are moved during servicing,
they must be returned to their original position and properly
secured.

CAUTION:

All electrical parts and wiring must be

shielded from torch flame. Do not allow torch to contact
insulation; it will char at 200°F.

NOTE:

Products come equipped with an Electronic Defrost

Control. To initiate defrost, press and hold air filter and alarm
reset key simultainiously for three seconds. To terminate defrost,
press and hold air filter and alarm reset key simultainiously for
three seconds

POWER

ICE MAKER

IC

E M

AKE

R

I

CE MAKER

ICE MAKER

WATER VALVE

LINE

THER MAL

CUT-OUT

HOLD

SW ITCH

T HERMOSTAT

SHUT-OF F

SWITCH

WATER FILL

SWITCH

MOLD HEATER

MOLD

MOUN TING

PLATE

MOTOR

NEUT RAL

BLK

BLK

B LK

BLK

BLU

LT. BLU

LT. BLU

BRN

RED

GRN / yEL

GRN / yEL

RED

YEL

YEL

YEL

P-3

P-1

P-2

P-4

Advertising