Electrolux EWG147540W User Manual

Page 19

Advertising
background image

2. If it is necessary, wait until the water

has cooled down.

A

B

3. Place a container close to the pump to

collect any spillage.

4. Release the emergency emptying hose

(B), place it in the container and re-
move its cap cover

5. When no more water comes out, un-

screw the pump cover (A) by turning it
anti-clockwise and remove the filter.
Use pliers, if necessary. Always keep a
rag nearby to dry up any water spill-
ages when removing the cover.
Clean the filter under a tap, to remove
any traces of fluff.

1

2

6. Remove foreign bodies and fluff from

the filter seat and from the pump impel-
ler.
Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it
doesn’t rotate, please contact your
Service Centre.

7. Put the cap back on the emergency

emptying hose and place the latter
back in its seat.

8. Replace the filter into the pump by in-

serting it correctly into the special
guides. Screw the pump cover firmly by
turning it clockwise.

1

2

Warning!

When the appliance is in use and depend-
ing on the programme selected there can
be hot water in the pump.

electrolux 19

Advertising