Before you call, 2 cabinet cleaning, 3 winter storage – Electrolux EXP09HN1WI User Manual

Page 16

Advertising
background image

16

www.electrolux.com

t Wash the filter using liquid dishwashing

detergent and warm water. Rinse filter
thoroughly. Gently shake excess water
from the filter. Be sure filter is thoroughly
dry before replacing.

t Or, instead of washing you may vacuum

the filter clean.

7.2 Cabinet Cleaning

t Be sure to unplug the air conditioner

to prevent shock or fire hazard. The
cabinet and front may be dusted with
an oil-free cloth or washed with a cloth
dampened in a solution of warm water
and mild liquid dishwashing detergent.
Rinse thoroughly and wipe dry.

t Never use harsh cleaners, wax or polish

on the cabinet front.

t Be sure to wring excess water from

the cloth before wiping around the
controls. Excess water in or around the
controls may cause damage to the air
conditioner.

7.3 Winter Storage

t If you plan to store the appliance during

the winter, cover it with plastic or return
it to its carton.

t For the model which with accessory

of storage cover, use it directly for the
appliance storage.

8. BEFORE YOU CALL

Air conditioner will not operate.

t Wall plug disconnected. Push plug

firmly into wall outlet.

t Plug Current Device Tripped. Press the

RESET button.

t House fuse blown or circuit breaker

tripped. Replace fuse with time delay
type or reset circuit breaker.

t Control is OFF. Turn Control ON and set

to desired setting.

t P1 appears in the display window.

Drain water as described in Drainage
Section.

t Shut off in Heat mode. When the air

outlet exceeds 70 °C (158 °F), the
automatic heat protection engages.
Romove any blockages and let
appliance cool down.

t Room Temperature lower than the set

temperature (Cool Mode). Reset the
temperature.

t Room Temperature higher than the set

temperature (Heat Mode). Reset the
temperature.

Air from unit does not feel cold
enough.

t Room temperature below 16 °C (60 °F).

Cooling may not occur until room
temperature rises above 16 °C (60 °F).

t Reset to a lower temperature.
t Compressor shut-off by changing

modes. Wait approximately 3 minutes
and listen for compressor to restart
when set in the COOL mode.

Air conditioner cooling, but room is
too warm - NO ice forming on cooling
coil behind decorative front.

t Outdoor temperature below 16 °C

(60 °F). To defrost the coil, set FAN
ONLY mode.

t Air filter may be dirty. Clean filter. Refer

to Care and Cleaning section. To
defrost, set to FAN ONLY mode.

t Temperature is set too low for night-

time cooling. To defrost the coil,
set to FAN ONLY mode. Then, set
temperature to a higher setting.

t Exhaust duct not connected or

blocked. See EXHAUSTING HOT AIR
Section.

Air conditioner cooling, but room is
too warm - ice forming on cooling coil
behind decorative front

t Dirty air filter - air restricted. Clean

air filter. Refer to Care and Cleaning
section.

t Temperature is set too high. Set

temperature to a lower setting.