• Do not let the power cable to heat up

to a temperature higher than 90° C.

Make sure that you connect the blue neu-
tral cable to the terminal with a letter "N"
on it. Connect the brown (or black) phase
cable to the terminal which has a letter
"L". Keep the phase cable connected at
all times.

8.3 Connection cable

Use only connection cable of type
H05V2V2-F T90 or equivalent type. Make
sure that the cable section is applicable to
the voltage and the working temperature.
The yellow/green earth wire must be ap-
proximately 2 cm longer than the brown
(or black) phase wire.

8.4 Building In

min.

55 mm

min.

650 mm

560 mm

480 mm

min.

100 mm

30 mm

10 mm

3 mm

11 mm

11 mm

A

A)

supplied seal

A

B

A)

supplied seal

B)

supplied brackets

CAUTION!
Install the appliance only on a
worktop with flat surface.

8.5 Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

B

A

A)

Removable panel

B)

Space for connections