COMMAND SUMMARY

Command

Command

Description

Key

A

Axis Select

selects the Active Axes

B

Base Speed

sets the Base speed

E

Encoder On/Off

either enable or disables the encoder

F

Finish Move

waits until motion has stopped and autocorrects

G

Go Index Number

indexes the number to index

H

Home

homes the motors

I

If Inputs...

loops to a line number if the Inputs match the value

J

Jump to Line

jumps to another line

L

Loop to Line

loop to another line a specified number of times

M

Max Speed

sets the Maximum Speed

N

Number to Index

sets the number to index

O

Set Outputs

sets the outputs

P

Go to Position

indexes to a given position

Q

Quit

stops program execution

R

Ramp

sets the ramp value

S

Set Position

sets the position value

T

Units (Scale)

sets the Scale Factor

U

Until inputs...

loops to a line until the Inputs match the value

V

Retries

sets the Encoder

W

Wait

waits a certain time before continuing on

Y

Encoder Window

sets the Encoder Window

Z

Encoder Resolution

sets the Encoder Resolution

±

Direction

sets the Direction

COMMAND DICTIONARY

AXIS SELECTION (any combination of A,B,C, OR D)
To select an Axis, type the Command Key 'A'. The Function Window will ask for the user to Enter the appropriate axes
to be Active. Enter the Letters 'ABCD' for all axes, or enter the Axis letters for any combination of Active Axes. The
default value for Active Axes is 'A'.

BASE SPEED (.001 to 2,50,000)
To select the Base Speed, type the Command Key 'B'. This command will set the Base Speed. The default for this
number is 50.

DIRECTION (+ or -)
To select the direction, type the Command Key '+' or '-'. This parameter specifies which direction the motor will turn when
indexed by the Go Command. The default value for this is '+' or the Clockwise Direction.

ENCODER ON/OFF (0 or 1)

Advertising