Securely tighten all screws and bolts, Securely tighten all screws, Adapting microwave blower – Bosch HMV3022U User Manual

Page 11: Adapting microwave blower for roof venting, Place the blower unit back into the opening, 9 caution, Adapting microwave blower for wall venting

Advertising
background image

11

5.

Confirm that the plate is properly centered and level.

6.

Securely tighten all screws, including the fifth wood

screw in the bottom area of the mounting plate.

Attaching the mounting plate

(wall stud at one corner hole)

1.

Insert the bolts and the wood screws into the mounting

plate through the holes designated.

2.

Attach toggle wings from the back of the mounting

plate onto each bolt. Leave enough space for toggle

wings to go through the wall and to open.

3.

Place the mounting plate against the wall and make

sure tabs are touching the bottom of the cabinet or the

level line (see "Aligning the mounting plate").

4.

Push the bolts through the drywall and finger tighten

the bolts to make sure toggle wings have opened

against drywall.

5.

Confirm that the plate is properly centered and level.

6.

Securely tighten all screws and bolts.

Attaching the mounting plate

(wall studs at both corner holes)

1.

Insert the wood screws into the mounting plate

through the holes designated.

2.

Place the mounting plate against the wall and make

sure tabs are touching the bottom of the cabinet or the

level line (see "Aligning the mounting plate").

3.

Confirm that the plate is properly centered and level.

4.

Securely tighten all screws.

Adapting microwave blower

This microwave is shipped assembled for Room Venting

Installation. The blower unit is already in place and must

not to be adapted.

Adapting microwave blower for roof venting

1.

Remove and save the screws holding the blower

motor and the blower plate. Lift up the blower plate

and put it aside.

2.

Carefully pull out the blower unit and rotate 90º so that

fan blade openings are facing out the top of the

microwave.

3.

Place the blower unit back into the opening.

9

CAUTION

Do not pull or stretch the blower unit wiring. Make

sure the wires are not pinched, and that they are

properly secured.

4.

Replace the blower plate and secure with the screws

removed in step 1.

5.

Attach the exhaust adapter to the top of the blower

plate by sliding it into the guides. Push in securely until

it is in the locking tabs. Make sure the damper hinge

swings freely.

Adapting microwave blower for wall venting

1.

Remove and save the screws holding the blower

motor and the blower plate. Lift up the blower plate

and put it aside.

2.

Carefully pull out the blower unit and rotate 90º so that

fan blade openings are facing out the top of the

microwave.

Advertising