In order to confirm that the device is operating correctly there is an indicate function installed.

By looking at the flash of the LED you can check the state of communication.

There are 2 flashing speeds, during standby on the secondary channel there is no flashing. If the primary

channel commences discovery, it will flash once every 3 seconds (for approx. 0.7 seconds). After

discovering the other device and communication becomes possible it will flash every 0.4 seconds.

Operating condition

LED

during connection standby

Low

during discovery

low speed

flashing

flashing once every 3 seconds

(for approx. 0.7 seconds)

during communication with

other device

high speed

flashing

switches from High to Low every 0.4

seconds

"#   

D-sub 9-pin Male connector: (RS-232C)

*** Electricity source:

a) With Voltage Regulator

b) Without Voltage Regulator

(U6_ is placed, R25 is removed)

(U6_ is removed, R25 is placed)

AC Adaptor DC 7.5V / 300mA above

DC 5V / 450mA above, stable source.

+ DC 5V

– Gnd

Pin No.

Name

Descriptions

I/O

1

DCD

Data Carrier Detect

I

2

RxD

Receiver Data

I

3

TxD

Transmitter Data

O

4

DTR

Data Terminal Ready

O

5

GND

Signal Ground

Gnd

6

DSR

Data Set Ready

I

7

RTS

Request to Send

O

8

CTS

Clear to Send

I

9

RI

Ring Indicator

I